WARNING !
When you are transferring hazardous fluids or the pump
temperature is over 60C, operator has to make precautions to
drain the fluid.
WARNING !
FIRE AND EXPLOSION HAZARD
If you are working with flammable fluids, be sure to take
precautions around the pump while cooling it. You must vent the
exhaust to a safe place
WARNING !
Diaphragm pumps are sold as pump unit only. Installing a
control device (if needed) is responsibility of the operator.
If the power supply of the pump (compressor) is stopped, the air
inlet to the pump must be cut off immediately. Otherwise when
compressor restarts, pump may start unexpectedly.
Manual operation: If the power supply of the pump
(compressor) is stopped, operator must cut off the air feed to
the pump manually. The operator must be informed and warned
about this.
Automatic operation: If the power supply of the pump
(compressor) is stopped, control unit must cut off the air feed to
the pump automatically. Installing this system is the
responsibility of the operator or the owner.
IMPORTANT NOTE :
If the diaphragm pump is submerged in water it is important that
the fluid will not enter the air exhaust system. To ensure this
please use the special exhaust cover with suitable attached hose
with hose exit not submerged in fluid.