8.
If ignition does not occur in 5 seconds, turn the regulator and LP tank valve
off, wait 5 minutes, and repeat the lighting procedure.
9.
Check the position of thermocouple,
make sure the flame has full contact
with the thermocouple.
Note: If thermocouple does not have full
contact with flame, unit will not stay lit.
10.
Cycle time for timer is around 15 minutes. If the timer is not reset within
around 15 minutes, the burner will shut OFF automatically. If this occurs,
please follow lighting instructions and continue to cook.
CAUTION
If burner does not light OR if burner flame is accidentally extinguished, turn knob to OFF,
wait 5 minutes, try again. If the burner does not ignite with valve open OR if burner flame
is accidentally extinguished after lighting, gas will continue to flow out of the burner and
could accidentally ignite with risk of injury.
Burner Flame Check
Light burner, rotate knob from HIGH to LOW. You should
see a smaller flame in LOW position than seen on HIGH.
Always check flame prior to each use. The air damper (D)
mounted on the back of your burner helps to control the
amount of primary air that mixes with the LP gas. A blue
flame with little or no yellow flame provides the best heat.
Adjust the air damper by turning it clockwise or
counterclockwise until the desired flame is achieved.
Turning LP Cooker Off
Turn all knobs to OFF position, Turn LP tank OFF by
turning hand-wheel clockwise to a full stop.