background image

-10-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

NOZZLE AND SPARK PLUG

Contaminated fuel, build-up of carbon, and accumulated dirt can affect the performance 

of these parts. Clean or replace these parts every 500 hours or as needed to ensure 

optimal performance of the heater.

REPLACING THE NOZZLE

1.  Remove Upper Shell.
2.  Disconnect Air and Fuel Lines from the Nozzle Rod.
3.  Remove ignitor wires from the Spark Plug.
4.  Remove  Spark  Plug  from  the  Nozzle  Rod  using  a  Phillips 

screwdriver.

5.  Twist the Nozzle Rod counterclockwise to remove it from the 

Burner Head.

6.  Carefully remove the Nozzle from the Nozzle Rod using a 5/8” 

socket wrench.

7.  Soak the nozzle in clean 1-K Kerosene to loosen particles.
8.  Inject compressed air into the front opening of the nozzle to 

loosen particulate.

 

WEAR SAFETY GLASSES.

9.  Install  new  (or  cleaned)  Nozzle  into  Nozzle  Rod  and  tighten 

firmly.

10.  Reassemble by reversing steps listed above.

REPLACING THE SPARK PLUG

1.  Remove Upper Shell.
2.  Remove igniter wire from Spark Plug.
3.  Remove Spark Plug from Nozzle Rod using medium Phillip screwdriver.
4.  Clean and re-gap the Spark Plug electrodes to 0.140 inches (3.5 mm) gap.
5.  Reinstall Spark Plug into Nozzle Rod.
6.  Attach igniter wires to Spark Plug.
7.  Secure Upper Shell.

Nozzle 

Rod

Nozzle Face

Nozzle Rod

Nozzle

Nozzle 

Rod

Spark Plug

Fuel Hose 

Fitting

Air Hose Fitting

Gap

FUEL FILTER

The Fuel Filter should be cleaned or replaced at the start of the season and 

as needed throughout the season to ensure optimal performance by the 

heater. Clean the Fuel Filter by rinsing the screen with clean 1-K Kerosene.
Replacing the Fuel Filter

1.  Remove  the  Right  Side  Panel  screws  using  a  medium  Phillips 

screwdriver.

2.  Remove Side Cover.
3.  Disconnect the Fuel Line from the Fuel Filter neck.
4.  Turn  Fuel  Filter  counterclockwise  90  degrees  using  an  adjustable 

wrench.

5.  Pull upwards and remove.
6.  Wash Fuel Filter with clean 1-K Kerosene.

Side Cover

Power Switch

Power Switch Wire

Screw

Fuel Filter

Fuel Line

SEASONAL MAINTENANCE SCHEDULE

Содержание R45K

Страница 1: ...ULATIONOFAUTHORITIES HAVING JURISDICTIONAND NFPA31 CANADIAN RESIDENTS THIS HEATER SHALL BE OPERATED IN ACCORDANCE WITH THE REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139 This is a...

Страница 2: ...breathing problems should consult a physician before using the heater Early signs of carbon monoxide poisoning resemble flu like symptoms such as headaches dizziness and or nausea If you have these s...

Страница 3: ...ROUNDED NEVER HANDLE HEATER WHILE HOT NEVER TRANSPORT HEATER WITH FUEL IN THE TANK WHEN USED WITH AN OPTIONAL THERMOSTAT OR IF EQUIPPED WITH A THERMOSTAT THE HEATER MAY START AT ANY TIME ALWAYS LOCATE...

Страница 4: ...ipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149 1 Periodically monitor levels of CO CO2 and NO2 existing at the construction site at the minimum at...

Страница 5: ...p 250V 10 Amp R215K Kerosene 210 000 BTU 7 0 PSI 13 2 Gal 1 58 gal h 120V 60Hz 2 7 Amp 250V 10 Amp UNPACKING 1 Remove the heater from the carton 2 Remove all packing materials applied to the heater fo...

Страница 6: ...DELS R45K AND R75K ONLY 1 Align the holes in the upper housing with the two mounting holes on the handle as shown 2 Secure handle through holes provided Screw Handle Interception Guard Interception Gu...

Страница 7: ...heater 1 fuel is a suitable substitute WARNING DO NOT START HEATER WHEN THE HEATER IS HOT DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMULATED IN THE CHAMBER NOT FOR USE WITH AN EXTERNAL FUEL TANK NE...

Страница 8: ...t start the thermostat setting may be lower than the ambient temperature Turn the Thermostat Control Knob to a higher temperature setting If the heater still does not start turn the Power Switch OFF W...

Страница 9: ...the filter Clean the filters every 500 hours as needed AIR OUTPUT FILTER AND LINT FILTER The Output and the Lint Filter are not designed to be cleaned and reused Do not wash these filters Replace dirt...

Страница 10: ...firmly 10 Reassemble by reversing steps listed above REPLACING THE SPARK PLUG 1 Remove Upper Shell 2 Remove igniter wire from Spark Plug 3 Remove Spark Plug from Nozzle Rod using medium Phillip screwd...

Страница 11: ...ment screw counterclockwise TROUBLESHOOTING POSSIBLE CAUSE CORRECTIVE ACTION E1 Photocell Flame Color Checking Sensor Error Oil Shortage Bad Photocell Flame Sensor Incomplete Combustion Contamination...

Страница 12: ...ever leave the heater unattended while operating Disconnect the heater from its power source when not in use CIRCUIT DIAGRAM Power Plug 5K PF125K 75K PF215K 250V 10A Power Plug 250V 10A R45K R75K R125...

Страница 13: ...NING Never leave the heater unattended while operating Disconnect the heater from its power source when not in use PARTS DIAGRAM 22 20 18 5 6 7 8 16 17 21 11 12 13 15 14 24 9 10 2 4 3 19 23 MODELS R45...

Страница 14: ...NG Never leave the heater unattended while operating Disconnect the heater from its power source when not in use 9 10 20 22 2 4 3 17 18 5 6 7 8 16 11 12 15 24 19 23 13 14 PARTS DIAGRAM MODELS R125K R1...

Страница 15: ...80729 11 Motor Pump Assembly R45K 80821 R75K 80742 R125K 80743 R175K 80744 R215K 80745 In order to maintain warranty components must be replaced using original manufacturer s parts purchased through...

Страница 16: ...ed maintained and operated in accordance with the instructions provided herein Furthermore PowerFast requires reasonable proof of the date of purchase from an authorized retailer or distributor This L...

Страница 17: ...raisonnable de la date d achat effectu e aupr s du fournisseur ou du distributeur autoris Cette garantie limit e ne couvre pas les checs ou les difficult s op rationnelles dus un usage r gulier et l...

Страница 18: ...Bougie d allumage 80729 11 Assemblage du moteur et de la pompe R45K 80821 R75K 80742 R125K 80743 R175K 80744 R215K 80745 Afin de maintenir la garantie les composants doivent tre remplac s avec les pi...

Страница 19: ...z jamais ce radiateur sans surveillance lorsqu il fonctionne Toujours d brancher ce radiateur lorsque vous ne l utilisez pas 9 10 20 22 2 4 3 17 18 5 6 7 8 16 11 12 15 24 19 23 13 14 SCH MA DES PI CES...

Страница 20: ...ssez jamais ce radiateur sans surveillance lorsqu il fonctionne Toujours d brancher ce radiateur lorsque vous ne l utilisez pas 22 20 18 5 6 7 8 16 17 21 11 12 13 15 14 24 9 10 2 4 3 19 23 SCH MA DES...

Страница 21: ...nterrupteur Thermostat Thermistance vert Bleu Bleu Lampe de combustion Af chage de la temp rature ambiante Cadran de contr le des TEMP Fusible Cellule photo lectrique Jaune Noir PCB PRINCIPAL Noir Noi...

Страница 22: ...Mauvaise cellule photo lectrique d tecteur de flamme Combustion incompl te Contamination du filtre de carburant chec d allumage Changez le carburant remplissez le radiateur si n cessaire V rifiez et...

Страница 23: ...nevis Phillips moyen 4 Nettoyez et resserrez les jauges d paisseur de la bougie d allumage des lectrodes pour obtenir un espace de 0 140 po 3 5 mm 5 R installez la bougie d allumage dans la sonde de l...

Страница 24: ...DE SORTIE D AIR La sortie et le filtre charpie ne sont pas con us pour tre nettoy s et r utilis s Ne pas laver ces filtres Remplacez les filtres sales au d but de chaque saison REMPLACER LES FILTRES...

Страница 25: ...secondes Placez l interrupteur en position ON MARCHE RED MARRER LE RADIATEUR APR S UN ARR T DE S CURIT 1 Mettez le bouton d alimentation en position OFF ARR T 2 D branchez le radiateur de sa source d...

Страница 26: ...Carburant no 1 l huile est un substitut ad quat AVERTISSEMENT NE PAS D MARRER LE RADIATEUR LORSQUE CELUI CI EST CHAUD NE PAS D MARRER LE RADIATEUR LORSQUE TROP DE CARBURANT S EST ACCUMUL DANS LA CHAM...

Страница 27: ...UR LES MOD LES R45K R75K 1 Alignez les trous du boitier sup rieur avec les trous de support dans la poign e comme indiqu 2 Fixez la poign e dans les trous Vis Poign e Interception Protecteur Intercept...

Страница 28: ...210 000 61 5 7 0 PSI 13 2 Gal 1 58 gal heure 120 V 60 Hz 2 7 A 250 V 10 amp D BALLAGE 1 Retirez le radiateur de la bo te 2 Enlevez tous les produits d emballage de la bo te associ s au radiateur 3 En...

Страница 29: ...on ou aux Codes d installation du gaz naturel et du propane CSA B149 1 Veuillez suivre p riodiquement les niveaux de CO CO 2 et NO 2 existant sur le site de construction au moins au d but du quart et...

Страница 30: ...MIS LA TERRE NE JAMAIS MANIPULER LE RADIATEUR LORSQU IL EST CHAUD NE JAMAIS TRANSPORTER CE RADIATEUR LORSQU IL CONTIENT DU CARBURANT DANS SON R SERVOIR LE RADIATEUR POURRAIT RED MARRER TOUT INSTANT LO...

Страница 31: ...PEUVENT COMPRENDRE ET RESPECTER CES INSTRUCTIONS DOIVENT UTILISER OU ENTRETENIR CE RADIATEUR SI VOUS AVEZ BESOIN D AIDE OU D INFORMATIONS SUR LE RADIATEUR COMME LE MANUEL D INSTRUCTION LES ETIQUETTES...

Страница 32: ...TES PAR LES AUTORIT S AYANT JURIDICTION ET PAR LA NORME CSA B139 Chau age De Construction Air Forc Au Mazout A Subsidiary of U S Stove Company 227 Industrial Dr South Pittsburg TN PH 423 837 5155 www...

Отзывы: