Electrical System
SALTWATER SERIES
DIGITAL SWITCHES 191, 223, 2000, 2200, 2300, 2310, 2400, 2410
Wake-up and Sleep Mode
To reduce power consumption, the keypad and power module can
shutdown their supply. In this mode, however, only the float switch of
automatic pump is powered. The system is put in wake-up mode when
any key of the keypad is pressed, ignition signal is on, or float switch is
activated.
When main 30A breaker is open, the keypad and power module are
not powered. DC Switching cannot activate its loads.
When the main 30A breaker is closed, the power module and the
keypad are powered. After 4 hours of no switch activity, if livewell pumps
are not in function and engine ignition is not activated, the power module
and the keypad will go in sleep mode.
Navigation and Anchor Lights
The navigation light switches on keypad control the operation of
navigation and anchor lights. On the first key press of the switch, both
navigation and anchor lights are turned on. On the second key press of
the navigation switch, navigation light turn off and anchor light remain on.
On the third press of the navigation switch, anchor turns off.The indicator
brightness will dim when navigation or anchor lights are on.
Aerator System
The livewell (labeled 1) and livewell timer switch control the rear
livewell. Pressing the livewell (1) switch on keypad turns on the rear well
fresh pump. Pressing the livewell (1) switch again will close both rear well
fresh pump and rear recirculate pump. When either rear pump is on, the
livewell timer can be used to start a periodic aeration cycle. Pressing the
livewell timer once starts the low aeration cycle of one minute on and two
minutes off. On a second key press of the livewell timer, the medium
aeration cycle of five minutes on and two minutes off. When a third press
of livewell timer, the high aeration cycle of 15 minutes on and two minutes
off starts. The fourth key press of livewell timer will turn off the timer
function. Rear activated pumps only will follow the cycle time.
Bilge System
The bilge switch on the keypad controls the bilge system. The float
switch always has power. Pressing the bilge switch once activates the
bilge pump by overriding the float switch. Pressing the switch a second
time deactivates the override output.
56
Содержание Fisherman Series
Страница 42: ...42 FISHERMAN SERIES...
Страница 43: ...43...
Страница 44: ...SALTWATER MODELS WITH DIGITAL SWITCHING 44...
Страница 45: ...45...
Страница 46: ...46 2000 WIRING...
Страница 47: ...47 47...
Страница 48: ...48 Z COMANCHE...
Страница 49: ...49...
Страница 50: ...50 168 169 WIRING DIAGRAM 168 CONSOLE PANEL SIMILAR TO 169...
Страница 68: ...Your RangerTrail Trailer 68 FIG 6 FIG 7...
Страница 72: ...72...
Страница 73: ...73...
Страница 77: ...MAINTENANCE NOTES 73...