EN
9
9
AIR OUTLET – RECIRCULATION VERSION
• Unfasten the 2 screws fixing the upper bracket
7.2.1
.
• Fasten the air outlet connector
15
in its place, using the 2
screws removed as above.
• Join the Connector
15
to the Hood canopy outlet using a
rigid or flexible pipe ø150 mm, selection of which is at
the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has
been fitted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch
having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance)
being sure that the connector of the feeding cable is cor-
rectly inserted in the socket placed on the side of the fan.
Flue assembly
Upper exhaust flue
• Slightly widen the two sides of the upper flue and hook
them behind the brackets
7.2.1
, making sure that they are
well seated.
• Secure the sides to the brackets by using the 4 screws
12c
(2,9 x 9,5) supplied.
• Make sure that the outlet of the extensions pieces is
aligned with the chimney outlets.
Lower exhaust flue
• Slightly widen the two sides of the flue and hook them
between the upper flue and the wall, making sure that
they are well seated.
• Fix the lower part laterally to the hood body by using the
2 screws
12c
(2,9 x 9,5) supplied.
12b