INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

Dear Installer

Before you start your installation, please complete the details 
below.

n

n

This hob is a Class 3 appliance.

Should your customer have a problem relating to your 
installation they will be able to contact you easily.

You must be aware of the following safety requirements & 
regulations:

Before installing, make sure that the local distribution 
conditions (nature of the gas and gas pressure) and the 
adjustment of the appliance are compatible.

This appliance must be installed in accordance with the 
regulations in force and only in a well-ventilated space. Read 
the instructions before installing or using this appliance.

The regulations and standards are as follows:

In the UK:

In your own interest and that of safety, it is law that 
all gas appliances be installed by competent persons. 
CORGI registered installers undertake to work to safe and 
satisfactory standards. Failure to install the appliance 
correctly could invalidate any warranty or liability claims and 
lead to prosecution. 

n

n

This appliance should not be installed in a boat or 
caravan.

The hob must be installed in accordance with:

• 

All relevant British Standards / Codes of Practice, in 
particular BS 5440 Part 2

• 

For Natural Gas – BS 6172 and BS 6891

• 

For LP Gas – BS 5482-1 (when the installation is in a 
permanent dwelling)

• 

The Gas Safety (Installation and Use) regulations

• 

The relevant Building / IET regulations

In the Republic of Ireland:

The installation must be carried out by a Competent Person 
and installed in accordance with the current edition of IS 813 
“Domestic Gas Installations”, the current Building Regulations 
and reference should be made to the current ETCI rules for 
electrical installation.

Provision of Ventilation

This appliance is not connected to a combustion products 
evacuation device. Particular attention shall be given to the 
relevant requirements regarding ventilation.

In the UK:

The room containing the hob should have an air supply 
in accordance with BS 5440 Part 2. All rooms require an 
openable window or equivalent, while some rooms require a 
permanent vent in addition to the openable window. The hob 
should not be installed in a bedsitting room with volume less 
than 20m³. If it is installed in a room of volume less than 5m³ 
an air vent of effective area 100cm² is required; if it is installed 
in a room of volume between 5m³ and 10m³, an air vent of 
effective area 50cm² is required; while if the volume exceeds 
11m³, no air vent is required.

If there are other fuel burning appliances in the same room, 
BS 5440 Part 2 should be consulted to determine the requisite 
air vent requirements.

In the Republic of Ireland:

Reference should be made to the current edition of IS 813, 
which makes clear the conditions that must be met to 
demonstrate that sufficient ventilation is available.

• 

DocNo.061-0004 - Installation RGG77 gas

ArtNo.050-0011 - Installer information table

Installer’s Name

Appliance Serial Number

Installer’s Telephone Number

Installer’s Company

5.  Installation

Содержание ECL60HPNGFBL/BL

Страница 1: ...ECL60HPNGFBL BL Gas on Glass Hob User Guide Installation Service Instructions U111052 02...

Страница 2: ......

Страница 3: ...tion of the Hob 9 Conversion 9 Checking the Parts 9 Positioning the Hob 10 Fixing the seal to the back of the hob 11 Fastening the Installation Brackets 11 Installing the Hob 11 6 Conversion to LPG 13...

Страница 4: ......

Страница 5: ...N Using a gas cooking appliance will result in the production of heat and moisture in the room in which it is installed Make that the kitchen is well ventilated keep natural ventilation holes open or...

Страница 6: ...er on grease fires and never pick up a flaming pan Turn off the controls and then smother a flaming pan on a surface unit by covering the pan completely with a well fitting lid or baking tray If avail...

Страница 7: ...k and light the gas If when you let go of the control knob the burner goes out then the safety device has not held in Turn the control to the off position and wait one minute then try again this time...

Страница 8: ...mended pan diameter is 120mm The maximum allowable pan base diameter is 250mm Hob Care The burner parts can be removed for cleaning see Cleaning your hob You should wipe the top surface of the hob aro...

Страница 9: ...t soapy water but take care that no surplus water seeps into the appliance Remember to switch on the electricity supply before re using the cooker Regular cleaning is recommended For easier cleaning w...

Страница 10: ...el Aluminium Hot soapy water and a soft cloth remove stubborn stains gently with a nylon scourer Cream cleaner and a nylon scourer dishwasher Cream cleaner and a nylon scourer dishwasher Cream cleaner...

Страница 11: ...y Is the power on If not there maybe something wrong with the power supply Are the sparker ignition electrode or burner slots blocked by debris Are the burner trim and caps correctly located See the s...

Страница 12: ...ations The relevant Building IET regulations In the Republic of Ireland The installation must be carried out by a Competent Person and installed in accordance with the current edition of IS 813 Domest...

Страница 13: ...area of the data badge this will identify the gas type the appliance is now set for This appliance is designed for domestic cooking only Use for any other purpose could invalidate any warranty or liab...

Страница 14: ...is being installed directly above a built in oven an additional spacer not supplied may be required to maintain a clearance of 10 mm between the underside of the built in hob and the top of the built...

Страница 15: ...ooktop is provided with an installation kit including brackets and screws for fastening the top to fixture panels from 20 to 40 mm thick Refer to Fig 5 4 1 Turn the cooktop upside down and fasten the...

Страница 16: ...have finished Front side Rear side R F Front Screw Rear Screw Knobs Front side F Rear side R Rear Screw R Rear Screw R Front Screw F Front Screw F seal A seal C Gas Connection Gas Connection Mains Co...

Страница 17: ...ction with the rest of the appliance instruction in particular for information on Standards cooker positioning connection hose suitability etc n n When servicing or replacing gas carrying components d...

Страница 18: ...label over the natural gas part of the appliance data label Pressure Testing Make sure that the appliance is gas sound The gas pressure can be measured at one of the hotplate burner injectors not the...

Страница 19: ...be connected to the gas supply system with one of the following A rigid steel pipe The joints of this pipe must consist of threaded fittings conforming to the standards The use of seals such as hemp w...

Страница 20: ...rts n n IMPORTANT Do not use a naked flame to test for leaks To maintain the thickness of 30 mm the hob is fitted with a channel to contain the connection pipe The gas inlet union can be turned in the...

Страница 21: ...It must be easy to inspect the entire pipe length in order to check its state of wear The pipe must be replaced within the date stamped on the pipe itself If in doubt contact your supplier After comp...

Страница 22: ...st the plug must not be used until a replacement cover has been obtained from your supplier The colour of the correct fuse carrier is that of the coloured insert in the base of the fuse recess or stat...

Страница 23: ...19 7 Circuit Diagram Brown Blue Yellow Green Yellow Green Blue Blue Red Micro Switch Spark 4 Spark 3 Spark 2 Spark 1 Igniter...

Страница 24: ...atural Gas 20 mbar 230V 50Hz Butane 29 mbar Propane 37 mbar See appliance data badge for test pressures Dimensions Outside Inside Width 500 mm 470 mm Length 580 mm 550 mm Depth 58 mm from top 46 mm Ma...

Страница 25: ...0 Type Gas Type of Hob GAS Number of gas burners 4 Wok EE gas burner 52 64 Semi rapide Medium Burner EE gas burner 60 20 Semi rapide Medium Burner EE gas burner 60 20 Rapide Large Burner EE gas burner...

Страница 26: ...liance started from the date of purchase of this product Any cosmetic damage to the appliance must be reported within 90 days of delivery Please note that AGA Rangemaster Limited have appointed UK War...

Страница 27: ...23 NOTE...

Страница 28: ...24 NOTE...

Страница 29: ...25 NOTE...

Страница 30: ...26 NOTES...

Страница 31: ...27 NOTES...

Страница 32: ...Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0 800 8046261 E mail consumers agarangemaster co uk...

Отзывы: