background image

Manual-7

RaneWare RW 232 Ethernet operation. Run RaneWare

(2.10 or higher) and from the System menu, select System
Setup. In the Connection box, select the Via 10 (Ethernet)
radio button so RW 232 commands will be sent out of the
Ethernet port (rather than out the PC’s RS-232 COM port nor
out the computer’s modem and phone line to a far end modem
and Rane’s RPD 1). Make sure to type the proper Via 10 IP
address for the RaneWare RW 232 device(s) you wish to
control over the network
. Each Via 10 can accept up to 16
RW 232 devices in any variety connected to its RS-232 port.
To address more RW 232 devices, use additional Via 10s.

Generic RS-232 use. RS-232 based serial devices can

transport their data through the Via 10 as long as the Via 10’s
RS-232 port is configured properly. The default settings for
the Via 10 RS-232 port are shown above. Supported ranges
for RS-232 communications can be found in the 

VIACONFIG

utility. The pull down fields display all supported settings.
For detailed RS-232 port specifications, see the Data Sheet
section of this Manual.

Standard RS-232/DB-9 wiring for Tx and Rx connections

are provided. The maximum cable length supported by RS-
232 is still 50 feet (15 meters); this assumes good quality,
CAT 5 cable.

A variety of external means are available to lengthen the

50 feet limitation by using RS-232 to RS-422 or RS-485
converter devices. These can be sourced from a variety of
manufacturers (but not Rane – we can’t make everything,
where would we put it? [OK, this is a Steven Wright joke, but
a good one
]). At this point, we’re compelled to ask: doesn’t it
seem strange to have to mention such devices when your
system already includes 100 meter-capable Ethernet for
control?

Hardware 2: RS-485, the Rane SR 1L and SRM 66

SR 1L Use. This Rane accessory is a generic RS-485

device. Though an accessory for the Rane SRM 66 Splitter
Router Mixer, SR 1L’s can be used independently for a
variety of applications. See Software and Applications on
page Manual-8.

Up to seven SR 1L Smart Remotes can be wired directly

to the Via 10 RS-485 port in any combination of daisy chain
or star configuration. Use CAT 5 cable (two twisted pairs plus
a shield) and double check the wiring since this is often the

cause of baldness (i.e., pulling our collective hair out debug-
ging problems
). Only the most distant SR 1L connected to the
Via 10 should have its R

T

 switch ON, which connects a 150

ohm terminating resistor.

SRM 66 Use. The SRM 66 contains an RS-485 port

(called RIP for Remote Interface Port) which may be wired to
the Via 10’s RS-485 port for SRM 66 control over a LAN;
however, you cannot connect both an SRM 66 and SR 1L
remote(s) to the same Via 10—one device per RS-485 port.
Do not connect the V+ terminals together—connect A to A, B
to B, V– to V– and shield to shield.

RS-485 remote power. The Via 10’s RS-485 port

includes a low current, 8 VDC supply which is required for
SR 1L operation, but can be used for powering other low
power peripheral devices. The data sheet (in this booklet) lists
the specifications for this small power source, including its
current capabilities.

Generic RS-485 Use. Use CAT 5 cable for connection to

the RS-485 port. The balanced data connections can drive up
to 100 meters of cable when properly terminated with 150
ohms to obey the standard and ensure trouble-free operation.

Hardware 3: Versatile Input Port (VIP)

The VIP provides the perfect place to connect memory

recall switches, potentiometers, temperature sensors and other
instrumentation and/or logic devices. Each of the eight inputs
accepts 0 to 5 VDC and includes a true 8-bit A-to-D converter
providing 256 steps; (it’s actually a 10-bit converter that is
rounded to an 8-bit word length
). You can therefore use each
of the eight VIPs as independently programmable compara-
tors, ratiometric controls or instrumentation inputs. A current-
limited (100 mA max) internal voltage reference of 5 volts
(Vref) is supplied. Each port includes a 100k ohm pull-up
resistor to Vref and a 2

nd

-order, 15 Hz Butterworth low pass

averaging filter. Any range of potentiometer values and tapers
can be used as long as the 100 mA current limitation is not
exceeded. Either momentary or position-sensitive switches
can be used; use whatever is appropriate or easiest for your
application and its software setup requirements. Any instru-
mentation output with a 0 to 5 VDC range can be used with
the VIP. The VIP update rate is dominated by the network
transmission speed and is read each time the VIP data is
requested using the 

Via10VIPX

 ActiveX control (see page

Manual-9).

VIP (Versatile Input Port)

INPUT BUFFER

(0 to 5 volts DC)

OCTAL 10 BIT A/D

+5VDC (100mA)

1

2

3

4

5

6

7

8

INTERNAL REFERENCE

REF

TO HOST CONTROLLER

SR 1L Smart Digital Remote Control

Содержание Via 10

Страница 1: ...d rear panel controls found on the Via 10 page Manual 2 Part two is Configuring the Via 10 PC page Manual 4 which explains what the Via 10 Config Utility does It also reviews the computer setup that is required so the computer can talk through the Via 10 s IP Internet Protocol language Part three goes over the Hardware details of the Via 10 s I O ports page Manual 6 Four sections are found RS 232 ...

Страница 2: ...r illuminates when there is activity on the Via 10 s RS 232 port 햴 RS485 indicator flashes when there is activity on the Via 10 s RS 485 port 햵 CONFIG button is recessed only used to set the Via 10 s IP address during initial setup See Configuring the Via 10 PC on page Manual 4 햶 PWR indicator lights when the Via 10 is powered It flashes when in Via 10 CONFIG mode ...

Страница 3: ...ble logic and or A D input port for use with external switches potentiometers or any zero to five volt instrumentation device Up to eight input devices in any variety are supported See the Hardware VIP section on page Manual 7 for further details 햷 Versatile Output Port VOP is a splendidly programmable open collector logic output port for use with external indicator lamps LEDs relays or any ground...

Страница 4: ...ernet adapter NIC or Network Interface Card installed in the PC If installed its operation may be checked by right clicking on My Computer followed by a left click on the selection Properties and again a left click on the Device Man ager tab of the System Properties dialog box Click on the plus sign to the left of Network Adapters to view the configured adapters A malfunctioning adapter is indicat...

Страница 5: ... web site www rane com then select Run from Windows Start menu and Browse to the floppy drive or file and double click SETUP to run the VIACONFIG install routine 2 If you power up a new Via 10 it comes up in config mode which is indicated by a flashing POWER LED If it s not already place the Via 10 in config mode by unplugging the power then hold in the Via 10 s front panel CONFIG button with a pe...

Страница 6: ...and Applications section on page Manual 8 Hardware 1 RS 232 the RW 232 RS 232 with Rane RW 232 The RS 232 port on the Via 10 can be hooked directly to the RW 232 Input port on any Rane RW 232 device allowing extended communication distances up to 305 feet 100 meters over a standard 10Base T Ethernet LAN ActiveX controls for commonly controlled parameters on the following Rane products are accessib...

Страница 7: ...e hair out debug ging problems Only the most distant SR 1L connected to the Via 10 should have its RT switch ON which connects a 150 ohm terminating resistor SRM 66 Use The SRM 66 contains an RS 485 port called RIP for Remote Interface Port which may be wired to the Via 10 s RS 485 port for SRM 66 control over a LAN however you cannot connect both an SRM 66 and SR 1L remote s to the same Via 10 on...

Страница 8: ...e an object a piece of software code which fully describes a device while hiding the implementation details such as protocol from the pro grammer By hiding the communication details there is no longer a need for different manufacturers devices to agree on protocol This lack of a protocol standard means that coopera tion between manufacturers is not required It allows each manufacturer to choose th...

Страница 9: ...ck or turning a system off at a certain time or adjusting delay time as the temperature changes Microsoft FrontPage 2000 ActiveX example Many use Microsoft s FrontPage 2000 to create user interface web pages for computer controlled systems These web pages may or may not be accessible over the Internet The examples found on Rane s web site will review the basic FrontPage 2000 procedures to link scr...

Страница 10: ...rontPage C Delphi or Lab View allow programming each VIP pin independently thus providing any combina tion of up to eight applications Thus with software scripts there is an unlimited number of possibilities for the VIP Use multiple hardware switches and or logic output ports on other system devices to recall system configurations or specific system settings Using scripts when a switch is closed a...

Страница 11: ...DoDisconnect Break connection to Via 10 RequestVIP Manually request VIP update Events OnVIP1Change Value on VIP 1 input changed OnVIP2Change Value on VIP 2 input changed OnVIP3Change Value on VIP 3 input changed OnVIP4Change Value on VIP 4 input changed OnVIP5Change Value on VIP 5 input changed OnVIP6Change Value on VIP 6 input changed OnVIP7Change Value on VIP 7 input changed OnVIP8Change Value o...

Страница 12: ...rol For SR 1L or generic RS 485 device communications on to and off of Ethernet 10Base T Control Name Via10SerialX Description General interface to Via 10 s Serial Ports RS 232 RS 485 Design Time Parameters Addr Via 10 s IP Address Port 0 RS 232 1 RS 485 Baud 0 300 1 1200 2 2400 3 4800 4 9600 5 19200 6 38400 Parity 0 Odd 1 Even 2 None Runtime Parameters BytesIn Number of bytes in the input buffer ...

Страница 13: ..._3 Value of SR 1L Address 3 0 31 Remote_4 Value of SR 1L Address 4 0 31 Remote_5 Value of SR 1L Address 5 0 31 Remote_6 Value of SR 1L Address 6 0 31 Remote_7 Value of SR 1L Address 7 0 31 Key Methods DoConnect Initialize a connection to the Via 10 Automatically sets the proper baud and parity for SR 1L use SendMem Sends a memory change to a Slaved SRM 66 Events OnError Called when an error occurs...

Страница 14: ... 2 s Level 0 32 Out2_In6 In 6 to Out 2 s Level 0 32 Out2_Master Out 2 s Master Level 25 85 Out2_Limiter Out 2 s Limiter Threshold 0 28 Out3_In1 In 1 to Out 3 s Level 0 32 Out3_In2 In 2 to Out 3 s Level 0 32 Out3_In3 In 3 to Out 3 s Level 0 32 Out3_In4 In 4 to Out 3 s Level 0 32 Out3_In5 In 5 to Out 3 s Level 0 32 Out3_In6 In 6 to Out 3 s Level 0 32 Out3_Master Out 3 s Master Level 25 85 Out3_Limit...

Страница 15: ... 0 7 Rmt5_Group Remote Address 5 s Group 0 7 Rmt6_Group Remote Address 6 s Group 0 7 Rmt7_Group Remote Address 7 s Group 0 7 Master_Group Groups to include in the Master Group 0 63 Group1 Group 1 Level 0 31 Group2 Group 2 Level 0 31 Group3 Group 3 Level 0 31 Group4 Group 4 Level 0 31 Group5 Group 5 Level 0 31 Group6 Group 6 Level 0 31 Master Master Group Level 0 31 Key Methods DoConnect Initialize...

Страница 16: ... Address 6 0 31 Remote_7 Value of SR 1L Address 7 0 31 Key Methods DoConnect Initialize a connection with the Via 10 This automatically sets the proper baud and parity rates for SRM 66 use SetMem Memory change for all slaved SRM 66s Events OnError An error occurred talking to the Via 10 Initialization DoConnect must be called to initialize a connection to the Via 10 RW 232 ActiveX control Required...

Страница 17: ...memory GetVUMeterSelect Returns VU Meter Select GetMasterPortDelay Returns Master Port Delay GetMasterMicDelay Returns Master Mic Delay GetPortSigRelease Returns Port Signal Release GetMicSigRelease Returns Mic Signal Release GetNearSigOffset Returns Near Signal Offset GetProgSigRelease Returns Program Signal Release GetProgSigOffset Returns Program Signal Offset GetProgSigThreshold Returns Progra...

Страница 18: ...hold SetPortOutputOn Port Value Sets a Port s Output Setting SetPortOutputAttenuation Port Value Sets a Port s Output Attenuation GetMixerEchoCancellerBypass Mixer Returns a Mixer s Echo Canceller Bypass GetMixerEchoCanceller3Kz Mixer Returns a Mixer s Echo Canceller 3KHz Setting GetMixerEchoCancellerEnhanced Mixer Returns a Mixer s Echo Canceller Enhanced Setting GetMixerGate Mixer Returns a Mixe...

Страница 19: ... connected to a Via 10 See RW 232 Device Control Language available in PDF form in the Library at www rane com for parameter value details Design Time Parameters Addr RW 232 Address 1 250 OpstatFreq Milliseconds between Opstat updates Runtime Parameters Memory Reflects the current memory selected in the RPE 228 Ch1InGain Channel 2 s Input Gain Ch1OutGain Channel 2 s Output Gain Ch1Mute Channel 2 s...

Страница 20: ...ompression Level for Input B MasterLevel Master Level InATrim Input A s Trim InAMute Input A s Mute InBTrim Input B s Trim InBMute Input B s Mute Out1Src Output 1 s Input Signal Source Out2Src Output 2 s Input Signal Source Out3Src Output 3 s Input Signal Source Out4Src Output 4 s Input Signal Source Out5Src Output 5 s Input Signal Source Out6Src Output 6 s Input Signal Source Out1Trim Output 1 s ...

Отзывы: