Installing the Tub (continued)

 

 

Step #7: 

Set tub back into place, re-check level.  

 

 

Make sure the unit is level prior to fastening to the floor. 
Do not over tighten the floor connections.  This could cause the unit to be un-level.

 

 

Step #8:

 

Make drain connection from sanitary tee on tub to facility drain.  
 

If mobile lifts are to be used for transferring patients, verify that the lift base 
clears the drain connection. If possible damage might occur to drain area, you 
must install blocking or a stop to prevent contact between lift base and plumbing.

 

 

Step #9: 

If tub has an air spa blower, plug the electrical cord into the GFI Outlet. 

 

Step #10:

 Attach any accessories, including shower wand and disinfect hose assembly as shown below. 

The shower hose is concealed inside tub, and can be pulled out. 
 

 

 

 

 
Step #11: 

Test unit for proper operation. Be sure to clean inside of tub prior to filling unit. Excess debris 

may damage the air blower. Check the unit for any leaks. 
 

Step #12: 

Remove any installation labels and directions. Clean tub and prepare for daily use with warm 

water and non-abrasive cleaner. 
 

NOTE: The thorough inspection and startup of the tub is required before first use. It is the 
installer’s responsibility to check for and tighten as necessary threaded connections on all parts of 
tub as part of this start-up procedure. 

 
 
 
 

____________________________________________________________________________________________ 

RANE

 RK12                                                                                                                       Page 3.3

 

Section

3

Attach Shower 
Wand Here 

Attach Disinfect Hose 
Assembly Here 

Содержание RK12

Страница 1: ...RK12 Bathing Tub Quick Reference Guide NOTHING S MORE REFRESHING THAN RANE Shown with optional equipment ...

Страница 2: ...sh the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed there is a ground current flowing indicating the possibility of an electric shock Do not use this hydromassaged tub Disconnect the hydromassaged bathtub and have the problem corrected by a qualified service representative b...

Страница 3: ...autifully contoured integral control panel provides convenient control of the bathing environment without the need for a wall mounted console The thermostatic mixing valve utilizes a maximum temperature setting feature to prevent accidental scalding Water flow to the tub is controlled by a 3 4 valve A 1 2 valve controls water flow to the hand held shower A solar thermometer measures the temperatur...

Страница 4: ...ng ____________________________________________________________________________________________ RANE RK12 Page 2 1 Vertical dimensions are with the tub in the lowest position The seat height is 19 If legs are extended and tub is raised adjust the dimensions accordingly 28 11 33 5 30 22 5 Note To Outside 3 5 ...

Страница 5: ...___________________________________________________________________ RANE RK12 Page 2 2 All connections made through access opening provided under tub Door hinge on right side of tub only Verify placement and door swing before final placement of unit SPACE REQUIREMENT TOP VIEW 75 8 Electrical cord with standard NEMA 5 15 Plug Allow for 13 5 for Access panel swing Allow for 40 Door Swing ...

Страница 6: ...re Installation Drawings and Dimensions Suggested Plumbing and Electrical Layout Section 2 ____________________________________________________________________________________________ RANE RK12 Page 2 4 ...

Страница 7: ... building codes and regulations This unit is a freestanding tub designed for easy access to controls by attendant Please review Section 2 for rough in dimensions and allow for spacing as listed plus any requirements for lifting devices Check all applicable building codes All electrical and plumbing work must be performed by qualified personnel Step 2 Remove all packing material and cardboard from ...

Страница 8: ...ower heads and accessories may become clogged or damaged if the lines are not clear Warranty does not cover damage caused by debris in the water lines Step 6 Connect the hot and cold water inlet hoses to facility plumbing Make sure that the hose screens are present see below and the hoses are not bent or kinked The threaded connections are NOT hose thread but rather National Pipe Thread NPT Sectio...

Страница 9: ...sories including shower wand and disinfect hose assembly as shown below The shower hose is concealed inside tub and can be pulled out Step 11 Test unit for proper operation Be sure to clean inside of tub prior to filling unit Excess debris may damage the air blower Check the unit for any leaks Step 12 Remove any installation labels and directions Clean tub and prepare for daily use with warm water...

Отзывы: