STANDARD UNIT:  MODEL # RK12 

PERFORMANCE DATA: 

SERVICE CONNECTIONS: 

MANUFACTURING AND TESTING: 

WARRANTY:  

____________________________________________________________________________________________ 

RANE

 RK12                                                                                                                       Page 1.1

 

Section

1

Tub Capacity: 

58 Gallons 

Occupied Tub Capacity (approx.): 

48 Gallons 

Thermostatic Mixing Valve: 

20 gpm 

Approximate Fill Time (48 gallons): 

2.4 min 

Drain Flow Rate: 

1.5” Drain-1.92 minutes        

Drain: 

2” inlet with a 1 1/2” PVC outlet 

Electrical for Air Blower Options: 

115V AC, 60Hz, 15A service with a GFI Circuit 
(not supplied by RANE) 

This unit is manufactured in Sparta, Tennessee,       
USA. Each unit passes a through quality control 
review and is tested for proper operation prior to 
shipping. This unit is manufactured to meet or           
exceed the following: ASME/ANSI A112.19.1M 
IAPMO/UPC, Canadian Standards Association

 

Please reference section 5 for complete warranty 
details. 

Description: 

Model RK12 is a freestanding, 58-gallon side access bathing tub. 

Construction: 

The tub shell consists of a 3/16” thick fiberglass-reinforced polyester laminate. Critical areas are 

reinforced with a 1/4” thick core of end-grain balsa and additional layers of fortifying laminate. The sanitary gelcoat is an 
ISO/NPG type-finish. Tub Frame is welded aircraft grade aluminum box tube. 

Side Access Door: 

The watertight right hinged door has a compression-type seal that is Teflon impregnated. 

Equipment Access Panel: 

A removable panel provides access to all plumbing and valves. 

Control Panel and Valves: 

The beautifully contoured integral control panel provides convenient control of the bathing 

environment without the need for a wall mounted console. The thermostatic mixing valve utilizes a maximum 
temperature setting feature to prevent accidental scalding.  Water flow to the tub is controlled by a 3/4" valve. A 1/2" 
valve controls water flow to the hand-held shower.  A solar thermometer measures the temperature of the water after it 
leaves the mixing valve and prior to discharging from the tub spout. 

Disinfection System:

 The built-in disinfection system eliminates the need for specifications and installation of a wall 

mounted system. A shelf for a gallon container of disinfectant chemical is provided under locked cabinet in the rear of 
the tub. The flow rate can be adjusted by a DEMA valve. The wand and hose are conveniently located to remain out of 
the way during bathing. 

Hand-Held Shower:

  A chrome, hand-held shower with flexible hose that retracts out of site is mounted to the deck of 

the tub. 

Drain and Overflow Assembly:

  An ample 1.5" drain is installed with an overflow. 

Grab Bars: 

One 7.5” grab bar is firmly mounted to the interior wall of the tub. A grab bar is also mounted on the inside 

of the side access door. 

Leveling Legs: 

The sturdy stainless steel leveling legs will adjust up to 2” per leg. 

Air Spa Option: 

The air spa system features a control system that allows for increasing the air flow at a gradual speed at 

the push of a button. A ceramic heating element provides warm air that helps maintains the water temperature and warms 
the surface of the tub. Backflow prevention spring loaded jets eliminate the need for back flushing air lines, providing for 
longer life than rubber flap style jets. 

 

Содержание RK12

Страница 1: ...RK12 Bathing Tub Quick Reference Guide NOTHING S MORE REFRESHING THAN RANE Shown with optional equipment ...

Страница 2: ...sh the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed there is a ground current flowing indicating the possibility of an electric shock Do not use this hydromassaged tub Disconnect the hydromassaged bathtub and have the problem corrected by a qualified service representative b...

Страница 3: ...autifully contoured integral control panel provides convenient control of the bathing environment without the need for a wall mounted console The thermostatic mixing valve utilizes a maximum temperature setting feature to prevent accidental scalding Water flow to the tub is controlled by a 3 4 valve A 1 2 valve controls water flow to the hand held shower A solar thermometer measures the temperatur...

Страница 4: ...ng ____________________________________________________________________________________________ RANE RK12 Page 2 1 Vertical dimensions are with the tub in the lowest position The seat height is 19 If legs are extended and tub is raised adjust the dimensions accordingly 28 11 33 5 30 22 5 Note To Outside 3 5 ...

Страница 5: ...___________________________________________________________________ RANE RK12 Page 2 2 All connections made through access opening provided under tub Door hinge on right side of tub only Verify placement and door swing before final placement of unit SPACE REQUIREMENT TOP VIEW 75 8 Electrical cord with standard NEMA 5 15 Plug Allow for 13 5 for Access panel swing Allow for 40 Door Swing ...

Страница 6: ...re Installation Drawings and Dimensions Suggested Plumbing and Electrical Layout Section 2 ____________________________________________________________________________________________ RANE RK12 Page 2 4 ...

Страница 7: ... building codes and regulations This unit is a freestanding tub designed for easy access to controls by attendant Please review Section 2 for rough in dimensions and allow for spacing as listed plus any requirements for lifting devices Check all applicable building codes All electrical and plumbing work must be performed by qualified personnel Step 2 Remove all packing material and cardboard from ...

Страница 8: ...ower heads and accessories may become clogged or damaged if the lines are not clear Warranty does not cover damage caused by debris in the water lines Step 6 Connect the hot and cold water inlet hoses to facility plumbing Make sure that the hose screens are present see below and the hoses are not bent or kinked The threaded connections are NOT hose thread but rather National Pipe Thread NPT Sectio...

Страница 9: ...sories including shower wand and disinfect hose assembly as shown below The shower hose is concealed inside tub and can be pulled out Step 11 Test unit for proper operation Be sure to clean inside of tub prior to filling unit Excess debris may damage the air blower Check the unit for any leaks Step 12 Remove any installation labels and directions Clean tub and prepare for daily use with warm water...