HAL1x
Multiprocessor
EXP
Expansion
Data Sheet - 19
DR5 Switch Controller
The DR5 Digital Remote offers additional logic input and
output ports, enabling the use of simple analog switch controls
in any HAL system. Lighted switch panels for room combine
applications are easily integrated into a HAL system using the
eight switch inputs and eight LEDs outputs on the DR5. Unlike
the HAL and DR4 Logic I/O, the DR5 Logic Out is intended
to drive the LED indicator on a room combine panel, and is a
writable parameter. The DR5 is designed to fit in a standard US
dual-gang electrical box, or mount directly near a room combine
panel.
DR5 Specifications
Parameter
Specification
Limit
Conditions/Comments
Switch Inputs
8
Small capsule
...Connector
Mini Euroblock
6-pin, 3.81 mm pitch, black
...Internal Pull-up
51.1 kΩ, 5.0 V
Protected to +24V, reverse polarity protected
...Vin High
> 2.0 V
min
Normal state
...Vin Low
< 0.9 V
max
External circuit must sink > 80 µA to assert
LED Outputs
8
...Connector
Mini Euroblock
6-pin, 3.81 mm pitch, black
...LED Drive Current
5 mA
typ
Driving an LED with Vf = 2.0 V
...Output High Voltage
5 V
typ
Output On, Current out = 0 mA
Ambient Room Temperature
104 °F / 40 °C
Maximum external loading
Unit Size
4.0
˝
H x 3.3
˝
W x 0.9
˝
D
10.2 x 8.4 x 2.3 cm (fits in 2-gang US electrical box)
CAT 5e
300 meters
1,000 feet
To a RAD or DR Port
on any HAL
or EXP unit.
L
S
G
L
S
G
Panel
Lock
option