background image

 

 

 

 
REMOTE RECALL 

The Remote Recall terminals on the rear of the unit are functionally equivalent to the Recall button. With a switch 
wired between the Recall terminal and the GND terminal, close the switch to recall Memory B. Open the switch to 
recall Memory A. 

  

In some situations it may be necessary to recall a stored setting or enable channel bypass from a location other than 
where the AD22S is located. Have a room divider wall? You can install a switch to select between the two room 
settings automatically when the wall is moved. Does the delay for your outdoor speaker array change with the 
temperature? Wire up a switch to change from a memory setting adjusted for one temperature to one saved for the 
other when the weather warms up. For these reasons we have provided remote recall connections on the rear of the 
unit that can be wired to standard switches installed in any other location.  

 
FIRMWARE UPDATE 

Should a firmware upgrade become available, it will be posted on the Rane website: 

rane.com

. The USB port 

provides the connection to a PC enabling the file transfer. Perform the following steps to update: 
1.

 

Ensure the unit is powered on. 

2.

 

Connect a USB cable from AD22S’s USB port to the USB port on a computer. 

3.

 

AD22S will appear as an external drive containing one file (named “AD22S_XX.BIN” or similar). 

4.

 

Delete this file.  

Note:

 After deleting this file, the folder may disappear, then re-open after a few seconds. 

5.

 

Copy or drag the new firmware file to the AD22S. 

6.

 

After transfer, AD22S will restart automatically and briefly display the new revision info.  

7.

 

Disconnect the USB cable and resume normal operation. 

Note: 

If the revision number displayed does not match the new firmware, make sure you have the latest file 

and try again.  

Tip:

 Press and hold both Cursor buttons simultaneously for one second to view the currently running firmware 

version. If an error occurs during transfer or a file is corrupted, the AD22S will revert to the last working version.

Содержание AD22S

Страница 1: ...AD22S User Guide English 3 9 Appendix English 10...

Страница 2: ...2...

Страница 3: ...easy access at any time Bypass relays for each channel automatically connect should the device lose power Your settings are always saved into working memory and restored upon power up Rear terminals l...

Страница 4: ...fectly with any video stream SETTING DELAY Use the Cursor and buttons to select the unit type then press the Coarse or Fine buttons to cycle through options In Distance mode choose between feet meters...

Страница 5: ...crements delay by 1 ms feet meters or 1 0 frames Fine increments or decrements delay by 0 1 ms feet meters or 0 5 frames 6 LCD Display Shows the current readout of settings for each channel Fields may...

Страница 6: ...n facilitates possible firmware upgrades in the future This port provides no other functions and should not be connected during normal use 6 Power Supply Connect the included power cable here Display...

Страница 7: ...as high as several frames or lead to noticeable synchronization issues While in Video mode the AD22S displays the delay time in the precise number of frames calculated for your current format and fram...

Страница 8: ...other location FIRMWARE UPDATE Should a firmware upgrade become available it will be posted on the Rane website rane com The USB port provides the connection to a PC enabling the file transfer Perform...

Страница 9: ...9 Appendix English Block Diagram both channels identical...

Страница 10: ...1 kHz Frequency Response 20 Hz 22 kHz 0 3 dB 4 dBu 20 Hz to 20 kHz System Gain High Impedance Load 600 Load 0 dB 0 5 dB Load 10 k balanced 4 dBu 20 Hz to 22 kHz 0 dB 0 1 dB Load 600 balanced 4 dBu 20...

Страница 11: ...11...

Страница 12: ...rane com Manual Version 1 0...

Отзывы: