TECHNICAL
DATA:
- Power supply: 230 Vac 50-60Hz 900W (4A) max.
- Flashing light output: 230 Vac 50-60 Hz
100W Resistive Load max.
50W Inductive Load max.
- Motor output: 230 Vac 50-60Hz 750 W max.
- Buffer battery input: 12 Vdc 2,7 A/h max.
- Alarm light output: 12 Vdc 2 W max.
- Power supply service output: 12 Vdc 5W max.
- Safety and BTcontrols: 12 Vdc
- Working temperature: -10 +55 °C
- Radio receiver: see model
- Op. transmitters: 12-18 Bit or Rolling code
- Max. TX codes in memory: 120 (CODE or CODE ALARM)
- Board dimensions: 140x145 mm.
- Box dimensions: 240x190x110 mm.
- Protection degree: IP 56.
CONNECTIONS OF TERMINAL BOARDS:
CN1 :
1 : 230 Vac input (phase).
2 : 230 Vac input (Neutral).
3 : 230 Vac flash input (Neutral).
4 : 230 Vac flash input (phase).
5 : Opening 230V motor output.
6 : Common 230V motor output.
7 : Closing 230V motor output.
CN2:
1 : Power supply/ Battery charger Alarm 13,8V.
2 : Alarm Control Output (positiv to miss).
3 : Power supply/ Battery charger Alarm signal GND.
CN3:
1 : Positive buffer battery input (+ 12V 2,7Ah max).
2 : Negative buffer battery input (- 12V 2,7Ah max).
3 : Signal light output (+ 12V 2W max).
4 : Signal light output (- 12V 2W max).
5 : AUX control contact output (NC) 30V 1A max.
6 : AUX control contact output (NC) 30V 1A max.
CN4:
1 : Power supply Photocells and Alarm sensors (+ 12V 5W).
2 : Power supply Photocells and Alarm sensors (GND).
3 : Input (Z2) Alarm zone 2 (NC).
4 : Input (Z1) Alarm zone 1 (NC).
5 : Common GND input.
6 : Input (DS) Safety motor Device (NC).
7 : Input (T) Tamper Alarm (NC).
8 : Common GND input.
9 : Input (P) Motor control Button (NA).
10: Ground Antenna input.
11: Hot pole Antenna input.
OPERATING FEATURES:
Using both the memorized radio-control (led CODE on) and the
Button (P) with low tension for the operation of doors and
windows, You will get the following operation:
The firs input rules the opening till the end of motor time or till
the Achievement of opening final run; the second input rules
the closure. If you send an input during the opening, before the
end of motor time Or the final run achievement, or if you send
an input during the Closing, before the end of motor time or the
final run achievement, The electronic unit will do the reversal
operation. Another input with stationary doors or windows
always represents A restart of the reversal operation.
Automatic closing:
The control unit closes the frame automatically without sending
other Commands. The choice of this operating mode is
described under The instruction for setting the delay period.
D.S.) Safety device (Photocells):
The control unit allows the connection and the control of
Photocells, Tyre sensors (NC).
- Input DS (NC):
During opening the operation of photocells is not contemplated,
During closing it causes the reversal movement.
Forced Closing:
In case of damage or malfunction of the Safety Device (Input
DS), the electronic panel automatically does a voluntary forced
closing of The frame. Using both the memorized radio control
(led CODE on) and the low tension button, you can do the
forced closing In the following way: to keep sending the
command for a higher time Of 5 seconds, then the frame starts
the closing till the run-end or till The end of motor time, but only
having pushing the move command.
With closed frame, the electronic panel turns to the normal
function.
Activation/Deactivation Alarm System (led CODE ALARM):
By manufacturing arragement, the electronic panel starts (15
Minutes after the end of the programmed motor time) and
Automatically cuts (immediately) the Alarm system of the close
or Open frame. Using the memorized radio control (led CODE
ALARM on), you can start or cut the Alarm system as you want.
Avoiding false activations or deactivations, the button of the
radio Control has to be pushed for at least 5 seconds. Then the
flashing Light (on for 3 seconds) and the Alarm light (10 rapid
flashes) will Show the choosen movement.
Z1 – Z2) Alarm Devices (zone 1 and zone 2):
It is possible to connect and supply 2 Alarm sensors (NC).
They can immediately activate the siren and the OUT AUX
Contact (NC).
T) Safety Device (Tampere):
It is possible to do the anti-split connection (Tampere) of the
siren and all the other alarm sensors (NC).
This can do the activation of the siren and the OUT AUX
contact (NC), even if the alarm system was cut by the CODE
ALARM Command.
Important: in case of maintenance, in order to cut the control
of The Tampere input, it will be necessary to swich to Installer
Mode (see the connected paragraph) before every operation
On the Alarm system.
Output (Sirens) from J1:
It is possible to connect standard sirens with supply for battery
charge upkeeping. With siren on, the battery supply is stopped
Or this can be caused by the related command (positive to
miss Default J1=1-2 or negative to miss J1=2-3).
Auxiliary Alarm Output (OUT AUX) from J2:
The electronic panel has an OUT AUX output (normally close
NC default J2=2-3 or normally open NA J2=1-2) for the
Connection of accessories or other present alarm systems.
The activation of the output will be simultaneous to the
activation Of the alarm till its switching off.
Light Alarm System:
It is possible to connect a light 12Vdc 2W max. to know the
alarm Status of the automation. Light off: alarm off; light on: 10
rapid Flashes for activations and disactivations and rapid light
with Lasting alarm for no electrical line, wireless sensor out of
Batteries or alarm on (also with time-signal mode).