background image

TECHNICAL

 

DATA: 

 

- Power supply:                     230 Vac 50-60Hz 900W (4A) max. 
- Flashing light output:                                    230 Vac 50-60 Hz 
                                                          100W Resistive Load max. 
                                                            50W Inductive Load max. 
- Motor output:                             230 Vac 50-60Hz 750 W max. 
- Buffer battery input:                                   12 Vdc 2,7 A/h max. 
- Alarm light output:                                          12 Vdc 2 W max. 
- Power supply service output:                          12 Vdc 5W max. 
- Safety and BTcontrols:                                                   12 Vdc 
- Working temperature:                                               -10 +55 °C 
- Radio receiver:                                                         see model 
- Op. transmitters:                                 12-18 Bit or Rolling code 
- Max. TX codes in memory:      120 (CODE or CODE ALARM) 
- Board dimensions:                                               140x145 mm. 
- Box dimensions:                                          240x190x110 mm. 
- Protection degree:                                                            IP 56. 

 

CONNECTIONS OF TERMINAL BOARDS: 

 

CN1 : 
1  : 230 Vac input (phase). 
2  : 230 Vac input (Neutral). 
3  : 230 Vac flash input (Neutral). 
4  : 230 Vac flash input (phase). 
5  : Opening 230V motor output. 
6  : Common 230V motor output. 
7  : Closing 230V motor output. 
 
CN2: 
1  : Power supply/ Battery charger Alarm  13,8V. 
2  : Alarm Control Output (positiv to miss). 
3  : Power supply/ Battery charger Alarm signal GND.

 

 
CN3: 
1  : Positive buffer battery input (+ 12V 2,7Ah max). 
2  : Negative buffer battery input (- 12V 2,7Ah max). 
3  : Signal light output (+ 12V 2W max). 
4  : Signal light output (- 12V 2W max). 
5  : AUX control contact output (NC) 30V 1A max. 
6  : AUX control contact output (NC) 30V 1A max.

   

 

 
CN4: 
1  : Power supply Photocells and Alarm sensors (+ 12V 5W). 
2  : Power supply Photocells and Alarm sensors (GND). 
3  : Input (Z2) Alarm zone 2 (NC). 
4  : Input (Z1) Alarm zone 1 (NC). 
5  : Common GND input. 
6  : Input (DS) Safety motor Device (NC). 
7  : Input (T) Tamper Alarm (NC). 
8  : Common GND input. 
9  : Input (P) Motor control Button (NA). 
10: Ground Antenna input. 
11: Hot pole Antenna input. 

 

OPERATING FEATURES: 
   
Using both the memorized radio-control (led CODE on) and the 
Button (P) with low tension for the operation of doors and 
windows, You will get the following operation: 
The firs input rules the opening till the end of motor time or till 
the Achievement of opening final run; the second input rules 
the closure. If you send an input during the opening, before the 
end of motor time Or the final run achievement,  or if you send 
an input during the Closing, before the end of motor time or the 
final run achievement, The electronic unit will do the reversal 
operation. Another input with stationary doors or windows 
always represents A restart of the reversal operation.

 

 
 
 

 
Automatic closing: 
 
The control unit closes the frame automatically without sending 
other Commands. The choice of this operating mode is 
described under  The instruction for setting the delay period.

 

 
D.S.) Safety device (Photocells): 
 
The control unit allows the connection and the control of 
Photocells, Tyre sensors (NC). 
- Input DS (NC):
 
During opening the operation of photocells is not contemplated, 
During closing it causes the reversal movement.

 

 
Forced Closing:
 
In case of damage or malfunction of the Safety Device (Input 
DS), the electronic panel automatically does a voluntary forced 
closing of The frame. Using both the memorized radio control 
(led CODE on) and the low tension button, you can do the 
forced closing In the following way: to keep sending the 
command for a higher time Of 5 seconds, then the frame starts 
the closing till the run-end or till The end of motor time, but only 
having pushing the move command. 
With closed frame, the electronic panel turns to the normal 
function.

 

 
Activation/Deactivation Alarm System (led CODE ALARM): 
By manufacturing arragement, the electronic panel starts (15  
Minutes after the end of the programmed motor time) and  
Automatically cuts (immediately) the Alarm system of the close 
or Open frame. Using the memorized radio control (led CODE 
ALARM on), you can start or cut the Alarm system as you want. 
Avoiding false activations or deactivations, the button of the 
radio Control has to be pushed for at least 5 seconds. Then the 
flashing Light (on for 3 seconds) and the Alarm light (10 rapid 
flashes) will Show the choosen movement.

 

 
Z1 – Z2) Alarm Devices (zone 1 and zone 2):
 
It is possible to connect and supply 2 Alarm sensors (NC).  
They can immediately activate the siren and the OUT AUX  
Contact (NC).

 

 

T) Safety Device (Tampere): 
It is possible to do the anti-split connection (Tampere) of the  
siren and all the other alarm sensors (NC). 
This can do the activation of the siren and the OUT AUX 
contact (NC), even if the alarm system was cut by the CODE 
ALARM Command. 
Important: 
in case of maintenance, in order to cut the control 
of The Tampere input, it will be necessary to swich to Installer  
Mode (see the connected paragraph) before every operation 
On the Alarm system.

 

 

Output (Sirens) from J1: 
It is possible to connect standard sirens with supply for battery 
charge upkeeping. With siren on, the battery supply is stopped  
Or this can be caused by the related command (positive to 
miss Default J1=1-2 or negative to miss J1=2-3).

 

 
Auxiliary Alarm Output (OUT AUX) from J2:
 
The electronic panel has an OUT AUX output (normally close 
NC default J2=2-3 or normally open NA J2=1-2) for the  
Connection of accessories or other present alarm systems. 
The activation of the output will be simultaneous to the 
activation Of the alarm till its switching off.

 

 

Light Alarm System: 
It is possible to connect a light 12Vdc 2W max. to know the 
alarm Status of the automation. Light off: alarm off; light on: 10 
rapid Flashes for activations and disactivations and rapid light 
with Lasting alarm for no electrical line,  wireless sensor out of 
Batteries or alarm on (also with time-signal mode).

 