Command Reference
R&S
®
ZNC
545
User Manual 1173.9557.02 ─ 13
<std_type>
Meaning
Parameters in [SENSe<Ch>:]CORRec-
tion:CKIT:<ConnType>:<Standard
-
Type>
MMATten | MFATten |
FFATten
Attenuation (m - m) or attenuation (m - f) or attenuation (f - f)
'<CalkitName>' ... <MaxFreq>[, <Port1>,
<Port2>]
no offset parameters, no load parameters
(polynomial coefficients), no OPEN |
SHORt | MATCh
MMSNetwork |
MFSNetwork |
FFSNetwork
Symmetric network (m - m) or symmetric network (m - f) or
symmetric network (f - f)
'<CalkitName>' ... OPEN | SHORt |
MATCh[, <Port1>, <Port2>]
no loss, otherwise complete parameter list
6.3.14.5
[SENSe:]CORRection:CKIT... with Labels
The following
[SENSe:]CORRection:CKIT...
commands identify the calibration kit
to be used by a combination of its <CalkitName> and <CalkitLabel>. Typically, the serial
number of the calibration kit serves as a calibration kit label. Due to their different labels,
the analyzer can handle several calibration kits with identical names.
............................................................545
...........................................................................546
...............................................................................546
.................................................................................546
...............................................................................547
...........................................................548
.......................................................548
[SENSe:]CORRection:CKIT:<ConnType>:LSELect
<CalKitName>, <Label>
Selects the calibration kit to be used for a specified connector type
<ConnType>
. The kit
is identified by its name and label.
Tip:
For connector types with arbitrary, user-defined names and labels you can use the
.
Suffix:
<ConnType>
.
Connector type, one of the following identifiers:
N50, N75
–
N 50 Ω or N 75 Ω connectors
PC7, PC35, PC292
–
PC 7, PC 3.5 or 2.92 mm connectors
USER<no>
–
user-defined connectors UserConn1, UserConn2
SMA
–
user-defined connector type SMA ...
Parameters:
<CalKitName>
String parameter containing the name of a calibration kit available
on the analyzer. See "Cal kit naming conventions " under
*RST:
n/a (A *RST does not change the assignment
between connector types and calibration kits.)
SCPI Command Reference