Configuring the R&S
TSMA6
R&S
®
TSMA6
34
Getting Started 4900.8040.02 ─ 07
●
The appropriate scanner license must be installed on the QualiPoc
®
handheld
device. If you do not have the correct license, contact the R&S service.
●
On the R&S
TSMA6, Bluetooth
®
must be activated and visible (see
).
To use the R&S
TSMA6 with QualiPoc
®
, the following steps must be performed.
1. Turn on the R&S
TSMA6 scanner.
2. In the web-GUI, set the "Mode of Operation" to "QualiPoc" and press "Sub-
mit".
3. On the handheld device, start the QualiPoc
®
application.
4. Touch the main menu , and then touch "Device manager"
5. Touch the plus sign (+) at the top of the screen and touch "NCM".
Figure 6-1: Add NCM
QualiPoc
®
displays "NCM" under "Devices".
Note:
The NCM provides the Bluetooth
®
connection to the scanner.
6. Touch "Scan" at the top of the screen and wait until the scanning process
stops.