Remote-Control Commands
R&S
®
SMCVB-K163
81
User Manual 1179.0997.02 ─ 02
S187|S203|S207
A sync byte (0x47) followed by 187/203/207 payload bytes.
H184|H200|H204
A sync byte (0x47) followed by three header bytes and
184/200/204 payload bytes.
*RST:
H184
Example:
See
Example "Configure and monitor TS player output"
Manual operation:
See
:TSGen:CONFigure:TSRate
<TSRate>
Sets the output data rate of the player.
Parameters:
<TSRate>
integer
Range:
1 to 35E7
*RST:
5018502
Example:
See
Example "Configure and monitor TS player output"
Manual operation:
See
:TSGen:READ:FMEMory
<FMemory>
Queries the file size of the TS player file.
Parameters:
<FMemory>
integer
Range:
0 to 10
*RST:
0
Example:
See
Example "Configure and monitor TS player output"
Manual operation:
See
:TSGen:READ:ORIGtsrate
<ORIGtsrate>
Displays the calculated original TS
data rate.
Parameters:
<ORIGtsrate>
integer
Range:
1 to 350000000
*RST:
5018502
Example:
See
Example "Configure and monitor TS player output"
Manual operation:
See
TSGen Subsystem