Remote-Control Commands
R&S
®
SMCVB-K163
64
User Manual 1179.0997.02 ─ 02
[:SOURce<hw>]:BB:DVBT:PID
<PID>
.
Parameters:
<PID>
integer
Range:
#H0000 to #H1FFF
*RST:
#H1FFF
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:DVBT:PIDTestpack
<PidTestPacket>
If a header is present in the test packet ("Test TS Packet > Head/184 Payload"), you
can specify a fixed or variable packet identifier (PID).
Parameters:
<PidTestPacket>
NULL | VARiable
*RST:
NULL
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:DVBT:PRBS[:SEQuence]
<PRBS>
Sets the length of the PRBS sequence.
You can select a PRBS 15 or a PRBS 23 sequence as specified by
Parameters:
<PRBS>
P15_1 | P23_1
*RST:
P23_1
Example:
See
Example "Configure test signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:DVBT:TESTsignal:LOW
<TestSignalLP>
[:SOURce<hw>]:BB:DVBT:TESTsignal[:HIGH]
<TestSignalHP>
Defines the test signal data.
Parameters:
<TestSignalHP>
TTSP | PBEC | PAFC
TTSP
Test TS packet with standardized packet data used as modula-
tion data in the transport stream.
Input Commands