background image

R&S

®

NGL200/NGM200

Power Supply Series

Getting Started

Getting Started

Version 04

 

1178872002

(;ÜåD2)

Содержание NGL200 series

Страница 1: ...R S NGL200 NGM200 Power Supply Series Getting Started Getting Started Version 04 1178872002 D2...

Страница 2: ...2019 Rohde Schwarz GmbH Co KG M hldorfstr 15 81671 M nchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data withou...

Страница 3: ...ic Safety Instructions and the product documentation in a safe place and pass them on to the subsequent users Riesgo de lesiones y da os en el instrumento El instrumento se debe usar de manera adecuad...

Страница 4: ...die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter Risque de blessures et d endommagement de l appareil L appareil doit tre utilis conform ment aux prescript...

Страница 5: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Страница 6: ...3 3 Unpacking and Checking the Instrument 13 3 4 Setting Up the Instrument 14 3 4 1 Bench Operation 14 3 4 2 Rack Mounting 15 4 Instrument Tour 16 4 1 Overview of Controls 16 4 1 1 Front Panel 16 4 1...

Страница 7: ...Contents R S NGL200 NGM200 4 Getting Started 1178 8720 02 04...

Страница 8: ...ssages and information on maintenance The online version html format of the user manual provides the complete con tents for immediate display on the internet Basic safety instructions Contains safety...

Страница 9: ...ues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbatim license texts of the used open source software See www rohde schwa...

Страница 10: ...ith overtemperature protection OTP This safety feature protects the R S NGL NGM from overheating When the temperature in the power supply exceeds the OTP limit the channel outputs are automatically cu...

Страница 11: ...Welcome to R S NGL NGM R S NGL200 NGM200 8 Getting Started 1178 8720 02 04 http www rohde schwarz com product ngl200 for R S NGL and http www rohde schwarz com product ngm200 for R S NGM...

Страница 12: ...e instrument casing Read and observe the Basic Safety Instructions delivered as a printed brochure with the instrument Note that the basic safety instructions also contain information on operating con...

Страница 13: ...ment results Electromagnetic interference EMI may affect the measurement results To suppress the generated EMI Use suitable shielded cables of high quality for example LAN cables Note the EMC classifi...

Страница 14: ...ed that a safe operation is no longer possible the instrument must be shut down and secured against any unintended operation Safe operation can no longer be assumed when Instrument shows visible damag...

Страница 15: ...rer without the product s ventilation being obstructed If the manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury and in some cases dea...

Страница 16: ...15 87 lb R S NGL202 R S NGM202 7 3 kg 16 09 lb 7 4 kg 16 31 lb 3 3 Unpacking and Checking the Instrument Unpack the R S NGL NGM power supply carefully and check the content of the package Check the eq...

Страница 17: ...instru ment in antistatic wrap to protect it from electrostatic charging Secure the instrument to prevent any movement and other mechanical effects during transportation Delivery package The package...

Страница 18: ...3 4 2 Rack Mounting The instrument can be installed in a 19 rack using the rack adapter R S HZN96 P N 3638 7813 02 Proceed according to the installation instructions supplied with the rack adapter Amb...

Страница 19: ...s 4 1 1 Front Panel The front panel of the R S NGL NGM is as shown in Figure 4 1 The function keys and navigation controls are located beside the display The various connec tors are located at the rig...

Страница 20: ...l keys 2 The menu control keys allow you to access the home window device channel menu window and user key in the instrument For a detailed description on menu control keys see section Menu Controls i...

Страница 21: ...screen shots Power key 7 The Power key switches the instrument on and off 4 1 2 Rear Panel Figure 4 2 shows the rear panel of the R S NGL NGM with its connectors Figure 4 2 Rear panel of R S NGL NGM...

Страница 22: ...connectors 9 10 Output terminals Either the output terminals at the front panel or those at the back panel can be used Using both terminals at the same time can cause instrument mal function Digital v...

Страница 23: ...O connector 15 The Digital I O option R S NGL K103 or R S NGM K103 must be installed for this function to be available in the instrument The specified voltages are 0 V to 24 V for all output pins and...

Страница 24: ...hure and safety measures in previous sections are observed Also check if the value on the voltage selector corresponds to the mains voltage 100 V 115 V or 230 V Fuse rating The R S NGL NGM uses the sa...

Страница 25: ...utput channels are turned off when the instrument is switched on to prevent connected loads from being damaged unintentionally During startup the R S NGL NGM is loaded with the last saved instrument s...

Страница 26: ...t menu see section Out put mode in the User Manual On the display sink mode is shown as negative current 5 1 Setting the Output Voltage and Current 1 Press Home key The R S NGL NGM displays the home w...

Страница 27: ...e the same as in source mode green if the current flowing into the R S NGL NGM is below the set current and red if the current is limited to the set value The only visible indication of sink mode is t...

Страница 28: ...strument damage caused by cleaning agents Use a dry lint free cloth to clean the product When cleaning keep in mind that the casing is not waterproof Do not use any liquids for cleaning Cleaning agent...

Страница 29: ...t 6 Overview of controls Front panel 16 Rear panel 18 P Putting into operation 9 Intended operation 12 Safety 10 Unpacking and checking the instrument 13 R Rear panel AC inlet with fuse holder 19 Chan...

Отзывы: