Remote Control
R&S
®
NGE100B
96
User Manual 5601.1343.02 ─ 02
Parameters:
<arg0>
ON | OFF | FUSetrip | CCMode | VOLTlevel | CURRlevel |
CRITevent | ARBitrary
ON
Trigger output is turned on.
OFF
Trigger output is turned off.
FUSetrip
Trigger output is linked to fuse tripped event.
VOLTlevel
Trigger output is linked to a set voltage level event.
CURRlevel
Trigger output is linked to a set current level event.
CRITevent
Trigger output is linked to a critical triggered event.
ARBitrary
Trigger output is linked to a EasyArb event.
*RST:
ON
TRIGger:OUT:CRITevent:DIO<IO>
<arg0>
This command sets or queries the critical event of the trigger output of the specified
Digital I/O line.
Suffix:
<IO>
.
1..4
Parameters:
<arg0>
OVP | OPP | OTP
OVP
Trigger output is linked to the OVP event
OPP
Trigger output is linked to the OPP event
OTP
Trigger output is linked to the OTP event
*RST:
OVP
TRIGger:OUT:CURRlevel:DIO<IO>
<Current>
This command sets or queries the threshold current level of the the trigger output of
the specified Digital I/O line.
Triggers when output current level exceeds or equals to the set level.
Suffix:
<IO>
.
1..4
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH