4 Maintenance

In case of functional errors, check the antenna for possible damage.

Visual inspection

Visual inspection is a basic check to verify that the hardware is not damaged. Check
the driven element, the directors and the reflector and the stabilizer bar for complete-
ness and visual damage.

If one of the elements mentioned is missing, bent, broken or torn off, the antenna has
to be repaired or replaced.

Electric functional test

An electronic functional test requires a network analyzer to measure the VSWR. The
test should be done in an empty room (no interfering, especially metallic, objects as
well as other persons should be present).

In case of a working antenna, the results should conform to the following specifications
in the antenna's specified frequency range (see 

Chapter 1, "Specifications R&S

®

HA-

Z900"

on page 4 and 

Chapter 2, "Specifications R&S

®

HA-Z1900"

on page 5).

VSWR < 2.5:1

If the antenna does not work as expected, contact the Rohde

 

&

 

Schwarz support.

 

Содержание HA-Z1900

Страница 1: ...HA Z1900 1328 6825 02 The R S HA Z900 and Z1900 are directional Yagi antennas They are easy to handle and designed as a passive receiving element in regulated frequency bands In combination with the...

Страница 2: ...y Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of...

Страница 3: ...Contents R S HA Z900 Z1900 3 Technical Information 1328 6490 02 01 Contents 1 Specifications R S HA Z900 4 2 Specifications R S HA Z1900 5 3 Operation 6 4 Maintenance 9...

Страница 4: ...1 Input 0 V DC 22 dBm RF Connector type N f Operating temperature range 10 C to 55 C Storage temperature range 40 C to 70 C Dimensions W x H x D 757 mm x 186 mm x 37 mm Weight 0 4 kg Mechanical resis...

Страница 5: ...1 Input 0 V DC 22 dBm RF Connector type N f Operating temperature range 10 C to 55 C Storage temperature range 40 C to 70 C Dimensions W x H x D 689 mm x 107 mm x 37 mm Weight 0 35 kg Mechanical resi...

Страница 6: ...g damaged Vibration and shock loads during mobile use must not exceed relevant data sheet specifications Depending on the degree and duration of the loading vibration and shock may shorten the product...

Страница 7: ...900 on page 4 and Chapter 2 Specifica tions R S HA Z1900 on page 5 for details Recommended measurement equipment Using the antenna requires an RF cable to connect it to a signal and spectrum ana lyzer...

Страница 8: ...handle and align it in the direction of the assumed signal and an arm s length away from your body Make sure to keep the orientation of the antenna and its directional elements stable during a measure...

Страница 9: ...broken or torn off the antenna has to be repaired or replaced Electric functional test An electronic functional test requires a network analyzer to measure the VSWR The test should be done in an empty...

Отзывы: