Remote commands to perform measurements in MSRA mode
R&S
®
FSWP-B1
87
User Manual 1177.5862.02 ─ 09
Manual operation:
See
[SENSe:]FREQuency:OFFSet
<Offset>
This command defines a frequency offset.
If this value is not 0
Hz, the application assumes that the input signal was frequency
shifted outside the application. All results of type "frequency" will be corrected for this
shift numerically by the application.
See also
Note:
In MSRA mode, the setting command is only available for the MSRA primary
application. For MSRA secondary applications, only the query command is available.
Parameters:
<Offset>
Range:
-1 THz to 1 THz
*RST:
0 Hz
Default unit: HZ
Example:
FREQ:OFFS 1GHZ
Manual operation:
See
9.4.1.4
Configuring the outputs
The following commands are required to provide output from the R&S
FSWP.
Configuring trigger input/output is described in
Chapter 9.4.2.2, "Configuring the trigger
..........................................................................................87
DIAGnostic:SERVice:NSOurce
<State>
This command turns the 28 V supply of the BNC connector labeled [noise source
control] on the R&S
FSWP on and off.
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
DIAG:SERV:NSO ON
Manual operation:
See
Configuring MSRA measurements