Measurements and Results
R&S
®
FSW
334
User Manual 1173.9411.02 ─ 43
Initial Measurement - Peak Search
.......................................................................340
Final Measurement at the Marker Position
........................................................... 341
7.13.3.1
Resolution Bandwidth and Filter Types
EMI testing requires resolution filters with a 6
dB bandwidth. The R&S
FSW EMI mea-
surement adds the following bandwidths that comply to commercial and military stand-
ards to those already available with the base unit:
Commercial (CISPR, FFC etc.)
●
200
Hz
●
9
kHz
●
120
kHz
●
1
MHz (not with Quasipeak detector, see
"Quasipeak detector (CISPR filter only)"
Military (MIL Std)
●
10
Hz
●
100
Hz
●
1
kHz
●
10
kHz
●
100
kHz
●
1
MHz
For the Quasipeak, CISPR Average, or RMS Average detector, the bandwidth is fixed
depending on the frequency. For more information see
7.13.3.2
Detectors and Dwell Time
The EMI measurement adds new detectors to those already available with the base
unit. The additional detectors are especially designed for and required by EMI applica-
tions.
The additional detectors are available only if the EMI (R&S
FSW-K54) measurement
option is installed and the filter type "CISPR" or "MIL" is selected (see
ter 7.13.3.1, "Resolution Bandwidth and Filter Types"
However, the EMI measurement need not be active.
The detector to be used for the initial peak search is configured in the trace settings
(see
Chapter 9.5.1.2, "Trace Settings"
on page 582), while the detector for the final
test is configured in the EMI marker settings, see
Chapter 7.13.4.1, "EMI Marker Con-
Dwell time
EMC tests often require a specific
dwell time
for an EMI measurement. The dwell time
defines how long the R&S
FSW measures the signal at the individual frequencies.