Measurements and Results
R&S
®
FSW
177
User Manual 1173.9411.02 ─ 43
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ALTernate<ch>
Alpha value:
[SENSe:]POWer:ACHannel:FILTer:ALPHa:CHANnel<ch>
[SENSe:]POWer:ACHannel:FILTer:ALPHa:ACHannel
[SENSe:]POWer:ACHannel:FILTer:ALPHa:ALTernate<ch>
Channel Names
In the R&S
FSW's display, carrier channels are labeled "Tx" by default; the first neigh-
boring channel is labeled "Adj" (adjacent) channel; all others are labeled "Alt" (alter-
nate) channels. You can define user-specific channel names for each channel which
are displayed in the result diagram and result table.
Remote command:
[SENSe:]POWer:ACHannel:NAME:ACHannel
[SENSe:]POWer:ACHannel:NAME:ALTernate<ch>
[SENSe:]POWer:ACHannel:NAME:CHANnel<ch>
7.2.5
MSR ACLR Configuration
Access
: "Overview" > "Select Measurement" > "Channel Power ACLR" > "CP / ACLR
Standard" > "Standard": "Multi-Standard Radio" > "CP / ACLR Config"
ACLR measurements can also be performed on input containing multiple signals for
different communication standards. A new measurement standard is provided that
allows you to define multiple discontiguous transmit channels at specified frequencies,
independent from the selected center frequency. If the "Multi-Standard Radio" standard
is selected (see
on page 169), the "ACLR Setup" dialog box is replaced by
the "MSR ACLR Setup" dialog box.
For more information, see
Chapter 7.2.3.4, "Measurement on Multi-Standard Radio
The remote commands required to perform these tasks are described in
ter 14.5.3, "Measuring the Channel Power and ACLR"
General MSR ACLR Measurement Settings
.........................................................177
MSR Sub Block and Tx Channel Definition
...........................................................183
.............................................................................. 185
......................................................................................188
........................................................................................... 193
7.2.5.1
General MSR ACLR Measurement Settings
Access
: "Overview" > "Select Measurement" > "Channel Power ACLR" > "CP / ACLR
Standard" > "Standard": "Multi-Standard Radio" > "CP / ACLR Config" > "MSR General
Settings" tab
Channel Power and Adjacent-Channel Power (ACLR) Measurement
Содержание FSW Series
Страница 1: ...R S FSW Signal and Spectrum Analyzer User Manual User Manual Version 43 1173941102 2...
Страница 16: ...Contents R S FSW 16 User Manual 1173 9411 02 43...
Страница 1388: ...Maintenance R S FSW 1388 User Manual 1173 9411 02 43 c If necessary remove any excess moisture with a dry soft cloth Cleaning...