Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
104
Operating Manual 1176.7610.02 ─ 02
The number of measurement to be executed for AVERage, MAXHold and MINHold is
defined with the
note that a synchronization to the end of the indicated number of measurements is only
possible during single sweep operation.
Note:
The setting is valid only for the currently active measurement (see
on page 96) and independent of the other Bluetooth measure-
ments.
Suffix:
<t>
.
the trace related to this setting
Parameters:
<Mode>
WRITe | VIEW | AVERage | MAXHold | MINHold | BLANk
*RST:
WRITe
Example:
INST:SEL BTO
Activates the Bluetooth Measurements option.
CONF:BTO:MEAS OPOW
Activates the Output Power measurement.
INIT:CONT OFF
Selects single sweep operation.
CONF:BTO:SWE:COUN 10
Sets the sweep count to 10.
CONF:BTO:TRAC2:MODE AVER
Switches averaging for trace 2 on.
INIT;*OPC
Starts a measurement with synchronization.
Mode:
BT
CONFigure:BTOoth:TRACe<t>:SELect
This command selects the measurement curve for evaluation of the modulation char-
acteristics.
Suffix:
<t>
.
the trace related to this setting
Example:
INST:SEL BTO
Activates the Bluetooth Measurements option.
CONF:BTO:MEAS ACLR
Activates the Adjacent Channel Power measurement.
INIT:CONT OFF
Selects single sweep operation.
CONF:BTO:TRAC2:SEL
Selects trace 2 for measurement result queries.
Mode:
BT
Manual operation:
See
CONFigure:BTOoth Subsystem (BLUETOOTH, K8)