Support
R&S
®
FSV-K70
342
Operating Manual 1176.7578.02 ─ 09
Figure 6-6: Example for adjusting the minimum gap length
For more information, see
●
The pattern search is switched on, fails and the alignment is with reference
to the pattern.
In case the pattern search is switched on and the reference for the alignment is the
pattern (and not the burst), a non-detected pattern causes the result range to be
positioned at the beginning of the capture buffer. Hence, if a the burst does not
start right at the beginning of the capture buffer, you will see a "Burst Not Found"
Message.
Solution:
–
Refer to
–
Switch the pattern search off.
–
Choose "Burst" as the reference for the result range alignment.
Message: Pattern Not Found
The "Pattern Not Found" error message can have several causes:
●
The burst search has failed
If burst and pattern search are active, the application looks for patterns only within
the found bursts. Hence, in case the burst search fails, the pattern search will also
fail.
Solution: Try one of the following:
–
Make sure the burst search is successful.
–
Deactivate the burst search but keep the pattern search active.
For more information, see
–
●
The offset of the pattern within the burst is incorrectly set
It is possible to set a pattern offset to speed up the pattern search. The offset of the
pattern would be the offset of the pattern start with respect to the start of the useful
part of the burst. However, if the entered offset is not correct (within about 4 sym-
bols of tolerance), the pattern will not be found.
Explanation of Error Messages
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...