Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
330
Operating Manual 1176.7578.02 ─ 09
Example:
TRIG:SOUR IFP
Sets the IF power trigger source.
TRIG:IFP:HOLD 200 ns
Sets the holding time to 200 ns.
Manual operation:
See
TRIGger<n>[:SEQuence]:IFPower:HYSTeresis
<Value>
This command sets the limit that the hysteresis value for the IF power trigger has to fall
below in order to trigger the next measurement.
Suffix:
<n>
.
irrelevant
Parameters:
<Value>
*RST:
3 dB
Example:
TRIG:SOUR IFP
Sets the IF power trigger source.
TRIG:IFP:HYST 10DB
Sets the hysteresis limit value.
Manual operation:
See
TRIGger<n>[:SEQuence]:HOLDoff[:TIME]
<Delay>
This command defines the length of the trigger delay.
A negative delay time (pretrigger) can be set in zero span only.
Suffix:
<n>
.
irrelevant
Parameters:
<Delay>
Range:
zero span: -sweeptime (see data sheet) to 30 s;
span: 0 to 30 s
*RST:
0 s
Example:
TRIG:HOLD 500us
Manual operation:
See
TRIGger<n>[:SEQuence]:SLOPe
<Type>
This command selects the slope of the trigger signal. The selected trigger slope
applies to all trigger signal sources.
Suffix:
<n>
.
irrelevant
Parameters:
<Type>
POSitive | NEGative
*RST:
POSitive
TRIGger subsystem
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...