Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
293
Operating Manual 1176.7578.02 ─ 09
Setting parameters:
<Name>
TYPE1 | TYPE2 | NORMal | DIFFerential
TYPE1 | NORMal
MSK
TYPE2 | DIFFerential
DMSK
*RST:
QPSK
Example:
DDEM:FORM MSK
Switches MSK demodulation on.
DDEM:MSK:FORM TYPE2
Switches DMSK demodulation on.
Mode:
VSA
Manual operation:
See
[SENSe:]DDEMod:NORMalize:ADRoop
<CompAmptDroop>
This command switches the compensation of the amplitude droop on or off.
Setting parameters:
<CompAmptDroop> ON | OFF
*RST:
ON
Example:
DDEM:NORM:ADR ON
Switches the compensation on.
Mode:
VSA
Manual operation:
See
[SENSe:]DDEMod:NORMalize:CFDRift
<CarrierFreqDrift>
This command activates or deactivates compensation of the carrier frequency drift.
Setting parameters:
<CarrierFreqDrift>
ON | OFF
*RST:
OFF
Mode:
VSA
Manual operation:
See
[SENSe:]DDEMod:NORMalize:FDERror
<RefDevCompensation>
This command selects the method for calculating the frequency error if you are using
FSK modulation.