![R&S CMW-KM5 Series Скачать руководство пользователя страница 473](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802473.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
473
User Manual 1173.9628.02 ─ 16
2.6.20 RLC Throughput Measurement
The following sections describe the commands related to the "RLC Throughput" mea-
surement.
Measurement Control and States
......................................................................... 473
.......................................................................................... 475
........................................................................................... 476
2.6.20.1
Measurement Control and States
The following commands control the measurement and return the current measure-
ment state.
INITiate:LTE:SIGN<i>:THRoughput
................................................................................. 473
.................................................................................... 473
...................................................................................473
FETCh:LTE:SIGN<i>:THRoughput:STATe?
......................................................................473
FETCh:LTE:SIGN<i>:THRoughput:STATe:ALL?
............................................................... 474
INITiate:LTE:SIGN<i>:THRoughput
STOP:LTE:SIGN<i>:THRoughput
ABORt:LTE:SIGN<i>:THRoughput
Starts, stops, or aborts the measurement:
●
INITiate...
starts or restarts the measurement; the R&S
CMW enters the
"RUN" state.
●
STOP...
causes a running measurement to stop after the current evaluation
period is terminated and valid results are available; the R&S
CMW enters the
"RDY" state.
●
ABORt...
causes a running measurement to stop immediately; the R&S
CMW
enters the "OFF" state.
Use
FETCh...STATe?
to query the current measurement state.
See also: "Measurement Control" in the R&S
CMW user manual, chapter "Remote
Control"
Example:
See
Performing an RLC Throughput Measurement
Usage:
Event
Firmware/Software:
V3.2.80
Manual operation:
See
FETCh:LTE:SIGN<i>:THRoughput:STATe?
Queries the main measurement state. Use
FETCh:...:STATe:ALL?
to query the
measurement state including the substates. Use
INITiate..., STOP...,
ABORt...
to change the measurement state.