1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
310
User Manual 1173.9511.02 ─ 11
Specifying General Measurement Settings
...........................................................310
Specifying Measurement-Specific Settings
...........................................................310
Performing Single-Shot Measurements
................................................................ 311
3.4.2.1
Specifying General Measurement Settings
//*************************************************************************
// System-Reset
//*************************************************************************
*RST; *OPC?
*CLS; *OPC?
//*************************************************************************
// Define signal routing and external attenuation
//*************************************************************************
ROUTe:EVDO:MEAS:SCENario:SALone RF1C, RX1
CONFigure:EVDO:MEAS:RFSettings:EATTenuation 2
WAITKEY >Signal routing and analyzer settings completed, press "OK" to continue<
3.4.2.2
Specifying Measurement-Specific Settings
//*************************************************************************
// Define two segments with a length of 20 slots each
// and different analyzer settings.
//*************************************************************************
CONFigure:EVDO:MEAS:MEValuation:LIST:COUNt 2
CONFigure:EVDO:MEAS:MEValuation:LIST:SEGMent1:SETup 20,1,
833.49E+6,OFF,ST2,BHSL,#H0,#H0,R11
CONFigure:EVDO:MEAS:MEValuation:LIST:SEGMent2:SETup 20,-10,
825.3E+6,ON,ST2,BHSL,#H1,#H1,R11
//*************************************************************************
// Enable modulation results for both segments
// and spectrum results for segment 2 only.
// Select an averaging length of 20 (all measured slots in the segment).
// Enable the list mode.
//*************************************************************************
CONFigure:EVDO:MEAS:MEValuation:LIST:SEGMent1:MODulation 20,ON,ON,
ON,ON,ON,ON,ON,ON,ON
CONFigure:EVDO:MEAS:MEValuation:LIST:SEGMent2:MODulation 20,ON,ON,
ON,ON,ON,ON,ON,ON,ON
CONFigure:EVDO:MEAS:MEValuation:LIST:SEGMent2:SPECtrum 20,ON,ON
CONFigure:EVDO:MEAS:MEValuation:LIST ON
Waitkey >List mode configuration complete, press "OK" to configure trigger<
//*************************************************************************
Programming
深圳德标仪器
135-1095-0799