1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
196
User Manual 1173.9511.02 ─ 11
Parameters:
<SNIncluded>
OFF | ON
*RST:
OFF
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
2.6.8.5
Connection Layer
The following parameters configure the connection layer. All settings are valid for sub-
type 0/1 and for subtype 2 signals.
This requires option R&S CMW-KS890.
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:PDTHreshold
........................................... 196
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:RLFoffset
.................................................196
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:ROMessages
........................................... 197
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:PDTHreshold
<PDThreshold>
Defines the pilot power (relative to the total "1xEV-DO Power") below which the AT
starts the pilot supervision timer and eventually announces that it has lost the network
connection.
Parameters:
<PDThreshold>
Range:
-31.5 dB to 0 dB
*RST:
-9 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:LAYer:CONNection:RLFoffset
<RLFOffset>
Delays the Reverse Traffic Data Channel and Reverse Rate Indicator Channel (RRI)
transmissions of the AT by an integer number of slots with respect to the system time-
aligned frame boundary.
Parameters:
<RLFOffset>
Range:
0 to 15
*RST:
8
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS890
Command Reference
深圳德标仪器
135-1095-0799