WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
657
User Manual 1173.9657.02 ─ 11
CONFigure:WCDMa:MEAS<i>:MEValuation:SCOunt:BER
<StatisticCount>
Specifies the statistic count of the measurement. The statistic count is equal to the
number of measurement intervals per single shot. Use
CONFigure:...:MEAS<i>:...:REPetition SINGleshot | CONTinuous
to
select either single-shot or continuous measurements.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<StatisticCount>
Number of transport blocks
Range:
1 to 1000
*RST:
100
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V1.0.4.11
Manual operation:
See
3.5.3.8
Trigger Settings
The following commands define the trigger parameters.
TRIGger:WCDMa:MEAS<i>:MEValuation:CATalog:SOURce?
............................................657
TRIGger:WCDMa:MEAS<i>:MEValuation:SOURce
........................................................... 658
TRIGger:WCDMa:MEAS<i>:MEValuation:SLOPe
..............................................................658
TRIGger:WCDMa:MEAS<i>:MEValuation:THReshold
........................................................658
TRIGger:WCDMa:MEAS<i>:MEValuation:TOUT
............................................................... 659
TRIGger:WCDMa:MEAS<i>:MEValuation:DELay
.............................................................. 659
TRIGger:WCDMa:MEAS<i>:MEValuation:MGAP
.............................................................. 659
TRIGger:WCDMa:MEAS<i>:MEValuation:CATalog:SOURce?
Lists all trigger source values that can be set using
.
Return values:
<TriggerList>
Comma separated list of all supported values. Each value is rep-
resented as a string.
Usage:
Query only
Firmware/Software:
V1.0.4.11
Manual operation:
See
Command Reference