WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
607
User Manual 1173.9657.02 ─ 11
// Query the carrier separation during dual carrier measurement.
// *****************************************************************************
CONFigure:WCDMa:MEAS:BAND OB3
CONFigure:WCDMa:MEAS:RFSettings:FREQuency 1162 CH
CONFigure:WCDMa:MEAS:RFSettings:DCARrier:SEParation?
3.4.1.2
Specifying Required Settings
// *****************************************************************************
// Specify required UE signal settings: presence of a DPDCH, slot format 1,
// scrambling code 5, channel configuration with HSUPA channels
// *****************************************************************************
CONFigure:WCDMa:MEAS:UESignal:DPDCh ON
CONFigure:WCDMa:MEAS:UESignal:SFORmat 1
CONFigure:WCDMa:MEAS:UESignal:CARRier1:SCODe 5
CONFigure:WCDMa:MEAS:UESignal:ULConfig HSUPa
3.4.1.3
Specifying Additional Measurement-Specific Settings
// *****************************************************************************
// Define stop condition (stop on limit failure) and error handling,
// select a measurement length of 30 slots (2 WCDMA frames),
// starting with slot 0 and using slot no. 3 as the preselected slot.
// Display slot 0 of the frame as first slot.
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEValuation:SCONdition SLFail
CONFigure:WCDMa:MEAS:MEValuation:MOEXception ON
CONFigure:WCDMa:MEAS:MEValuation:MSCount 30
CONFigure:WCDMa:MEAS:MEValuation:PSLot 3
CONFigure:WCDMa:MEAS:MEValuation:SYNCh SL0
// *****************************************************************************
// Specifiy modulation/CDP settings:
// Full-slot measurement over 20 statistics cycles,
// analysis without origin offset, channel detection threshold -5 dB,
// statistical results in slot 4, spreading factor 16, query detection mode,
// set offset 45° for I/Q constellation diagram.
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEValuation:MPERiod:MODulation FULL
CONFigure:WCDMa:MEAS:MEValuation:SCOunt:MODulation 20
CONFigure:WCDMa:MEAS:MEValuation:AMODe:MODulation NOOF
CONFigure:WCDMa:MEAS:MEValuation:CDTHreshold:MODulation -5
CONFigure:WCDMa:MEAS:MEValuation:SSCalar:MODulation 4
CONFigure:WCDMa:MEAS:MEValuation:DSFactor:MODulation SF16
CONFigure:WCDMa:MEAS:MEValuation:DMODe:MODulation?
CONFigure:WCDMa:MEAS:MEValuation:ROTation:MODulation 45
// *****************************************************************************
// Specify spectrum settings:
Programming