WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
514
User Manual 1173.9657.02 ─ 11
CONFigure:WCDMa:SIGN<i>:EHICh:REPetition
<Repetition>
Specifies the repetition mode of the measurement. The repetition mode specifies
whether the measurement is stopped after a single-shot or repeated continuously. Use
to define the number of subframes
to be measured per single shot.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot:
Single-shot measurement
CONTinuous:
Continuous measurement
*RST:
SING
Example:
See
Configuring the E-HICH Measurement
Firmware/Software:
V3.0.20
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:EHICh:MFRames
<MeasFrames>
Defines the number of subframes to be measured per measurement cycle (statistics
cycle).
Parameters:
<MeasFrames>
Range:
100 to 1E+6
Increment: 100
*RST:
1000
Example:
See
Configuring the E-HICH Measurement
Firmware/Software:
V3.0.20
V3.2.10: changed minimum value
Options:
R&S CMW-KS401
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:EHICh:LIMit
<FalseRatio>
Specifies limits for the results of the E-HICH measurement.
Parameters:
<FalseRatio>
Upper limit for E-HICH reception "False Ratio" result
Range:
0 % to 100 %
*RST:
1 %
Default unit: %
Example:
See
Configuring the E-HICH Measurement
Command Reference