Measurement Types and Result Displays
R&S
®
NRX
79
User Manual 1178.5566.02 ─ 07
Data Source
Available if "Measure" is set under
Selects the trace.
Remote command:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Marker>:FEED:INDex
Reference Marker
Defines a marker as reference marker.
Remote command:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Marker>:REFerence
Measurement Mode
Available if "Measure" is set under
Defines the measurement. The marker result is displayed under
.
"Trace Value "
Measures the power of the trace.
Marker result is "p".
"Power Ratio to Ref"
Measures the power ratio in relation to the reference marker.
Marker result is "
Δ
p".
"Time Diff to Ref"
Measures the time difference in relation to the reference marker.
Marker result is "
Δ
t".
"Average Power to Ref"
Measures the average power between time positions of the marker
and its reference marker.
Marker result is "Pav".
Remote command:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Marker>:FUNCtion
7.4
Pulse Analysis
Supported by wideband power sensors. Use this measurement type for automatic
analysis of pulsed signals. You can measure either power over time over the whole
trace, or restrict the measurement to a defined portion of the pulse signal. Trigger each
trace separately.
.................................................................................80
...........................................................................................80
..............................................................................................81
Pulse Analysis