Measurement Types and Result Displays
R&S
®
NRX
75
User Manual 1178.5566.02 ─ 07
7.3.2
Trace Settings
Access: "Measurement Settings"
> "Measurement Type"
> "Trace"
................................................................................................ 76
Display
See
Chapter 6.1, "Display Settings"
Pos / Scaling
Defines the effect of the cursor keys on the displayed trace.
"Pos"
Shifts the position. Press one of the cursor keys to shift the trace in x-
and y-direction.
"Scaling"
Changes the scaling. Press one of the cursor keys to expand or com-
press the trace.
Autoscale
Adapts the scaling of the power axis to the trace. The scaling of the time axis is adap-
ted only if the power sensor supports it.
Info / Marker
Shows or hides additional information below the graph.
"Info"
Displays measurement settings.
"Marker"
Displays the marker results according to the set measurement, see
on page 79. If you tap here, the "Trace
Marker" dialog opens, see
Chapter 7.3.3, "Trace Marker Dialog"
on page 76.
Shows buttons to select a marker, see
Remote command:
M1 / M2 / M3 / M4
Shows the selected marker in the trace.
Remote command:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Undef>:SELection
Trace