6.6
Fall Stop Assembly
6.6.1
General
The slack fall stop is a safety stop, not a functional stop. The fall stop must be located at least 3 feet [91.4
cm] from end of last chain link.
Figure 18. Fall Stop Assembly
6.6.2
Fall Stop Installation
1. Position two fall stop halves (item 3 – Figure 18) on chain link at least 3 feet [91.4 cm] from end of
load chain. Attach end of chain to chain container strap with snap clip provided.
2. Insert bolt (item 2) through two halves and attach nut (item 3). Tighten per section 7.4.
FALL STOP
36-INCH MINIMUM
SNAP CLIP