OM-51000 & 53000 SERIES 9
Installation
ELECTRICAL SUPPLY
Any wiring should be done by a qualified electrician in accordance with local electrical
codes. A properly wired and grounded outlet will assure proper operation. Please
consult the data tag attached to the compressor to ascertain the correct electrical
requirements. Supply voltage and amperage requirements are located on the serial
number tag located inside the mechanical housing.
BULLET-FEET ADJUSTMENT
The legs are equipped with bullet-type leveling bolts. Turn bolts clockwise or
counterclockwise until the unit is level (both right to left and front to back). This can be
done by hand or with an open end wrench.
IT IS IMPORTANT THAT A VOLTAGE READING
BE MADE AT THE COMPRESSOR MOTOR
ELECTRICAL CONNECTIONS, WHILE THE UNIT
IS IN OPERATION TO VERIFY THE CORRECT
VOLTAGE REQUIRED BY THE COMPRESSOR
IS BEING SUPPLIED. LOW OR HIGH VOLTAGE
CAN DETRIMENTALLY AFFECT OPERATION
AND THEREBY VOID ITS WARRANTY.
IT IS IMPORTANT THAT YOUR UNIT HAS
ITS OWN DEDICATED LINE. CONDENSING
UNITS ARE DESIGNED TO OPERATE WITH
A VOLTAGE FLUCTUATION OF PLUS OR
MINUS 10% OF THE VOLTAGE INDICATED
ON THE UNIT DATA TAG. BURN OUT OF A
CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
Содержание 51000 Series
Страница 21: ...OM 51000 53000 SERIES 21 Electrical Schematic ALL MODELS EXCLUDING 51386 51395 PASS THRU UNITS ...
Страница 22: ...22 OM 51000 53000 SERIES Electrical Schematic MODELS 51386 51395 ...
Страница 23: ...OM 51000 53000 SERIES 23 Electrical Schematic ALL PASS THRU MODELS 51347PT 35 52 51368PT 35 52 ...
Страница 25: ...OM 51000 53000 SERIES 25 ...
Страница 26: ......
Страница 27: ......