Unit Operation 

Your display merchandiser's temperature is adjusted by a cold control which for the 40026 

is located on top of the unit and on the 4030GA is located directly behind the louvered 

panel on the access side of the merchandiser. It is important to keep the doors closed as 

much as possible. This is especially important in the summer and when ambient 

temperatures exceed 80

°

 F. to help reduce the chance of condensation forming on the glass 

and to increase the efficiency of the merchandiser. 

Note: Even though your display case was designed for heavy use, excessive door openings 

should be avoided, in order to maintain proper box temperature and eliminate the 

possibility of coil freeze up.

 

Preventive

 

Maintenance 

Randell strongly suggests a preventive maintenance program which would include the 

following

 Monthly

 procedures: 

1. Cleaning of all condenser coils. Condenser coils are a critical component in the life 

of the compressor and must remain clean to assure proper air flow and heat transfer. 

Failure to maintain this heat transfer will affect unit performance and eventually 

destroy the compressor. Clean the condenser coils with coil cleaner and/or a vacuum 

cleaner and brush. 

Note: Brush coil in direction of fins, normally vertically as to not damage or restrict 

air from passing through condenser.

 

2. Clean all fan blades, both on the condensing unit and the evaporator assembly. 

3. Lubricate door hinges with lithium grease. 
4. Clean and disinfect drain lines and evaporator pan with a solution of warm water 

and bleach. 

5. Clean all gaskets on a weekly if not daily basis with a solution of warm water and 

a mild detergent to extend gasket life. 

NOTE:  DO NOT USE SHARP UTENSILS 

 

 

 

 

12 

 

Содержание 40000 Series

Страница 1: ...ignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a notation o...

Страница 2: ...r superior products is the result of consistent quality craftsmanship From the earliest stages of product design to successive steps in fabrication and assembly rigid standards of excellence are maint...

Страница 3: ...pecifications without prior notice Notice Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied Model Number ___...

Страница 4: ...RANDELL MANUFACTURING SERIAL NUMBER LOCATIONS FOR THE 4030GA 40026SSA This is a sample of a serial number tag The serial number tag is located on the outside cabinet 4...

Страница 5: ...40026SSA 4030GA 40026SSA Model L D H Style HP Volt AMP NEMA Ship Wt 4030GA 30 27 28 Counter top 1 3 115 60 1 7 5 15P 240 40026A 26 24 39 Pass thru 1 4 115 60 1 5 5 15P 240 40026SSA 26 24 39 Single se...

Страница 6: ...ss or specialty methods of shipping is the responsibility of the customer Labor Coverage In the unlikely event a Randell manufactured unit fails due to defects in materials or workmanship within the f...

Страница 7: ...ive compressor sent back freight prepaid 4 Furnish complete condensing unit or replacement package freight collect in exchange for the return of the defective compressor sent back freight prepaid deci...

Страница 8: ...cretion of the Randell in house service technician Gasket Coverage Randell does not cover gaskets under warranty Gaskets are a maintenance type component that are subject to daily wear and tear and ar...

Страница 9: ...ser The following conditions should be considered when selecting a location for your unit 1 Countertop load The countertop on which the merchandiser will display rest must be free of vibration and sui...

Страница 10: ...ty D Door Inspection 1 Check doors to ensure that they are sealing properly 2 Check doors for proper alignment 3 Check doors to ensure that they open and shut freely E Installation Checklist After the...

Страница 11: ...cabinet temperature remains to warm and your temperature control is at the maximum setting you may need to adjust the pressure control Your units pressure control should be set at the time of install...

Страница 12: ...ts a preventive maintenance program which would include the following Monthly procedures 1 Cleaning of all condenser coils Condenser coils are a critical component in the life of the compressor and mu...

Страница 13: ...VER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can...

Страница 14: ...ions Tighten or adjust shrouds 4 Tighten and isolate as needed 5 Call service agency D Temperature too high 1 Check power cord and circuit breaker 2 Temperature control set too high 3 Dirty condenser...

Страница 15: ...PONENTS RF CMP333 136 CONDENSOR 10 1 4 X 8 X 3 1 8 RFCOI115 137 CONDENSOR FAN MOTOR EL MTR085 138 CONDENSOR FAN BLADE 6 4 BLADE RF FAN011 140 FILTER DRYER 1 4 LINE RF FLT250A 141 CONDENSATE PAN W CLAM...

Страница 16: ...o drafting service 4030g dgn Aug 20 1998 10 02 58...

Страница 17: ...o drafting service 4030g dgn Aug 26 1998 14 42 23...

Страница 18: ...MODEL 4030G PARTS DIAGRAM o drafting service 4030g dgn Aug 20 1998 09 26 59...

Страница 19: ...DOOR FRAME HEATER 82 LONG EL WIR 256 78 FLOURESCENT LIGHT FIXTURE 20 RP LGT426F 79 BALLAST ELBLS100 92 ALUMINIZED PAINTED LID FOR UNIT 18 X 25 3 4 RP LID 426 94 LIGHT PANEL 11 1 2 X 26 COMPLETE W FIX...

Страница 20: ...VAPORATOR FAN MOTOR EL MTR590 159 EVAPORATOR FAN BLADE RF FAN005 162 FAN MOUNTING BRACKET 12 3 4 RP BRK427 407 PLEXI GLASS LIGHT PANNEL 26 X 9 3 4 RP PNL426 407 GLASS SEE THRU 25 1 4 X 24 HD GLS144 51...

Страница 21: ...o drafting service 40026 dgn Aug 28 1998 08 00 36...

Страница 22: ...o drafting service 40026 dgn Aug 26 1998 14 37 34...

Страница 23: ...o drafting service 40026 dgn Aug 26 1998 14 40 42 MODEL 40026 REFRIGERATOR CONDENSER PARTS DIAGRAM...

Страница 24: ...UPPLY 2120 Solona St Ft Worth TX 76117 0009 1 800 433 1804 DEPOT 4 GENERAL PARTS 11311 Hampshire Ave South Bloomington MN 55438 1 800 279 9980 DEPOT 5 COMMERCIAL PARTS 5310 E 25th Street P O Box 18688...

Отзывы: