C. Electrical

 

Supply

 

The wiring should be done by a qualified electrician in accordance with local electrical 

codes. A properly wired, and grounded outlet will assure proper operation. Please consult 

the data plate attached to the compressor to ascertain the correct electrical 

requirements. Supply voltage and amperage requirements are located on the serial number 

tag. 

Note: It is important that a voltage reading be made at the compressor motor electrical 

connections, while the unit is in operation, to verify that the correct voltage 

required by the compressor is being supplied. Low or high voltage can detrimentally 

affect operation and thereby void its warranty.

 

Note: It is important that your unit has its own dedicated line. Condensing units are 

designed to operate with a voltage fluctuation of plus or minus 10% of the voltage 

indicated on the unit data plate. Burn out of a condensing unit due to exceeding 

voltage limits will void the warranty.

 

D. Door Inspection

 

1. Check doors to ensure that they are sealing properly. 
2. Check doors for proper alignment. 

3. Check doors to ensure that they open and shut freely. 

E. Installation

 

Checklist

 

After the final location of the display merchandiser has been determined refer to the 

following checklist prior to start up: 

1. Check all exposed refrigeration lines to ensure that they are not kinked, dented or 

rubbing together. 

2. Check that condenser and evaporator fans rotate freely without striking any stationary 

members. 

3. Unit must be properly leveled. 
4. Plug unit in and turn on main power switch and/or cold control. 

5. Refer to the front of this manual for serial number location. Please record this 

information in your manual on page 3 now. It will be necessary when ordering 

replacement parts or requesting warranty service. 

6. Confirm that unit is holding temperature. Set controls to desired temperature for your 

particular ambient and altitude. 

7. Allow your display merchandiser to operate for approximately 2 

hours before putting in food. This allows interior to cool 
down to the correct storage temperature.  

 

Note:   All motors are oiled and sealed. 

 

 

 

10 

Содержание 40000 Series

Страница 1: ...ignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a notation o...

Страница 2: ...r superior products is the result of consistent quality craftsmanship From the earliest stages of product design to successive steps in fabrication and assembly rigid standards of excellence are maint...

Страница 3: ...pecifications without prior notice Notice Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied Model Number ___...

Страница 4: ...RANDELL MANUFACTURING SERIAL NUMBER LOCATIONS FOR THE 4030GA 40026SSA This is a sample of a serial number tag The serial number tag is located on the outside cabinet 4...

Страница 5: ...40026SSA 4030GA 40026SSA Model L D H Style HP Volt AMP NEMA Ship Wt 4030GA 30 27 28 Counter top 1 3 115 60 1 7 5 15P 240 40026A 26 24 39 Pass thru 1 4 115 60 1 5 5 15P 240 40026SSA 26 24 39 Single se...

Страница 6: ...ss or specialty methods of shipping is the responsibility of the customer Labor Coverage In the unlikely event a Randell manufactured unit fails due to defects in materials or workmanship within the f...

Страница 7: ...ive compressor sent back freight prepaid 4 Furnish complete condensing unit or replacement package freight collect in exchange for the return of the defective compressor sent back freight prepaid deci...

Страница 8: ...cretion of the Randell in house service technician Gasket Coverage Randell does not cover gaskets under warranty Gaskets are a maintenance type component that are subject to daily wear and tear and ar...

Страница 9: ...ser The following conditions should be considered when selecting a location for your unit 1 Countertop load The countertop on which the merchandiser will display rest must be free of vibration and sui...

Страница 10: ...ty D Door Inspection 1 Check doors to ensure that they are sealing properly 2 Check doors for proper alignment 3 Check doors to ensure that they open and shut freely E Installation Checklist After the...

Страница 11: ...cabinet temperature remains to warm and your temperature control is at the maximum setting you may need to adjust the pressure control Your units pressure control should be set at the time of install...

Страница 12: ...ts a preventive maintenance program which would include the following Monthly procedures 1 Cleaning of all condenser coils Condenser coils are a critical component in the life of the compressor and mu...

Страница 13: ...VER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can...

Страница 14: ...ions Tighten or adjust shrouds 4 Tighten and isolate as needed 5 Call service agency D Temperature too high 1 Check power cord and circuit breaker 2 Temperature control set too high 3 Dirty condenser...

Страница 15: ...PONENTS RF CMP333 136 CONDENSOR 10 1 4 X 8 X 3 1 8 RFCOI115 137 CONDENSOR FAN MOTOR EL MTR085 138 CONDENSOR FAN BLADE 6 4 BLADE RF FAN011 140 FILTER DRYER 1 4 LINE RF FLT250A 141 CONDENSATE PAN W CLAM...

Страница 16: ...o drafting service 4030g dgn Aug 20 1998 10 02 58...

Страница 17: ...o drafting service 4030g dgn Aug 26 1998 14 42 23...

Страница 18: ...MODEL 4030G PARTS DIAGRAM o drafting service 4030g dgn Aug 20 1998 09 26 59...

Страница 19: ...DOOR FRAME HEATER 82 LONG EL WIR 256 78 FLOURESCENT LIGHT FIXTURE 20 RP LGT426F 79 BALLAST ELBLS100 92 ALUMINIZED PAINTED LID FOR UNIT 18 X 25 3 4 RP LID 426 94 LIGHT PANEL 11 1 2 X 26 COMPLETE W FIX...

Страница 20: ...VAPORATOR FAN MOTOR EL MTR590 159 EVAPORATOR FAN BLADE RF FAN005 162 FAN MOUNTING BRACKET 12 3 4 RP BRK427 407 PLEXI GLASS LIGHT PANNEL 26 X 9 3 4 RP PNL426 407 GLASS SEE THRU 25 1 4 X 24 HD GLS144 51...

Страница 21: ...o drafting service 40026 dgn Aug 28 1998 08 00 36...

Страница 22: ...o drafting service 40026 dgn Aug 26 1998 14 37 34...

Страница 23: ...o drafting service 40026 dgn Aug 26 1998 14 40 42 MODEL 40026 REFRIGERATOR CONDENSER PARTS DIAGRAM...

Страница 24: ...UPPLY 2120 Solona St Ft Worth TX 76117 0009 1 800 433 1804 DEPOT 4 GENERAL PARTS 11311 Hampshire Ave South Bloomington MN 55438 1 800 279 9980 DEPOT 5 COMMERCIAL PARTS 5310 E 25th Street P O Box 18688...

Отзывы: