background image

 

DE

Manuale per il tecnico

Manuel destiné au technicien

Handbuch für den Techniker 

Technician’s Manual

Manual para el tecnico 

Macchina per caffè

Machine à café

 

Kaffeemaschinen

Coffee machine

Máquina para café

Máquina para café

classe 8

Manuale per il tecnico

Manuel destiné au technicien

Handbuch für den Techniker 

Technician’s Manual

Manual para el tecnico 

Manual para o técnico

 

Содержание Classe 8 S

Страница 1: ...nician s Manual Manual para el tecnico Macchina per caff Machine caf Kaffeemaschinen Coffee machine M quina para caf M quina para caf classe 8 Manuale per il tecnico Manuel destin au technicien Handbu...

Страница 2: ...in diesem Handbuch beschrieben werden d rfen nur von ausgebildeten Technikern durchgef hrt werden The interventions and the programming procedures described in this manual may only be carried out by...

Страница 3: ...display language 4 2 Visualize and reset the total calculations 4 3 Dose programmation 4 4 Check distribution time 4 5 International settings 4 6 Cleaning 4 7 Visualize date and pressure 4 8 Adjust bo...

Страница 4: ...is discontinued auto matically after 3 minutes if the set tempe rature has not yet been reached 1 MAKING COFFEE 1 1 Number of Dispensers The coffee maker is equipped with 4 coffee dispen sers with pr...

Страница 5: ...he menu Or to quit programming mode 5 Button Key off 8 SEC enter esc CLOCK SET DATE SET HOUR FORMAT DATE HOUR SET TIMER STAND BY TIMER SUN 8 7 1 Clock Sub menu to set date and time and mode 24 hours o...

Страница 6: ...pressed to start washing until the display shows Group Cleaning press ENTER If you press enter within 10 seconds the following cycle starts if you do not leave this menu automa tically The display sh...

Страница 7: ...To browse from one menu to another press or to enter a sub menu or to confirm a variation press enter to exit press esc The value that can be modified with or keys is flashing 4 TECHNICIAN PROGRAMMAT...

Страница 8: ...French Spanish German Portuguese 4 2 Visualize and reset the total calculations The calculations for each selection made are visua lized and requested whether to set the counters to zero or not 4 3 D...

Страница 9: ...t distribution after varying a dose the time of each distribution is stored This time is compared during the following distributions and will be displayed for a t12 time at the end of the distribution...

Страница 10: ...ng level ranging from 1 to 12 Also for non whipped milk in addition to the final temperature a slight whipping can be set ranging from 1 to 12 4 10 Align probes Boiler temperature probe alignment This...

Страница 11: ...ated to the water level in the boiler not reached in the fixed time the following is shown In case of intervention of the safety device related to the heating time longer than the fixed time the follo...

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...eilweise oder gesamte Nachdruck dieses Handbuches ohne schriftliche Genehmigung der Fa RANCILIO SPA ist verboten Die firma RANCILIO beh lt sich vor eventuell notwendige nderungen jederzeit durchzuf hr...

Отзывы: