Rancilio CLASSE 10 Скачать руководство пользователя страница 8

8

Once dispensing has ended, the following comes up 

on display:

-  OK (if the dispensing time is comprised in ± 15% 

of the time stored)

-  Deviation time in seconds 

(if  the  dispensing 

time is out of the ± 15% tolerance)

In  both  of  these  functions,  the  display  shows  pro-

gressive  cup  fill-up  based  on  the  impulses  being 

dispensed.

5.2.1.4 Enable programming

To enable or disable the dose programming function 

in auto-tuning mode (User Manual par. 9.1.1).

5.2.1.5 International settings

Setting the following measure units:

-  Temperature  [Celsius or Fahrenheit]
-  Pressure 

[bar or psi]

-  Resin unit 

[French  degrees/litres  or  Grains/

Grains Gallons]

5.2.1.6 Strength reduction

Enabling this function will reduce the boiler resistance 

strength by 2/ of its rated capacity.

6000W 20V => 4000W 20V
400W 20V => 2870W 20V
200W 120V => 210W 120V

5.2.1.7 Regeneration of the filter resins

To enable the filter resins regeneration message, it is 

necessary to set the water mains hardness and the 

water treatment unit’s resins volume.
If the volume is set at 0, the function is disabled.

5.2.1.8 Preventive maintenance

To enable the programmed maintenance message on 
display, it is necessary to set the number of relative 
cycles (i.e. dispensing cycles) or the relative months 
of machine operation.
The  reset  function  serves  to  deactivate  the  mainte-
nance message so that it is not displayed.

5.2.1.9 Boiler sensor

Setting the type of boiler pressure sensor:
-  Temperature sensor
-  Pressure transducer (default)

5.2.1.10 Level sensor

Sets the type of boiler water level sensor:
-  Level indicator rod
-  Capacitive board (default)

5.2.1.11 Error codes log

Display of the machine error logs (ref. par. 9). Displays 

the error code, with relative date and time.

5.2.1.12 first-time start up

Setting, at coffee machine first-time start up, of the 

machine’s configuration menu (ref. par. 4). Any first-

time start up data set previously, remain stored into 

the system.

5.2.1.13 Technical menu access block

Provides the option of blocking access to the technical 

menu via password “1927”.

5.2.1.14 Software versions

Displays  the  software  versions  installed  into  the 

machine.

5.2.2  counters

5.2.2.1 Brew count

By enabling the output counting, the counter would 

account for the coffees output by multiplying by 2 the 

output started with the 2-coffee keys, and counting 

also the interrupted outputs.

The 5

th

 key onto the coffee keyboards does not start 

any output continuously, but it works as Stop only.   

By disabling the counting, any single key is accounted 

for, and the 5

th

 key operates as  Start/Stop only.

5.2.2.2 Selection counter

This displays the counters for each coffee group, the 

water group, the iSteam group and the total of the 

counters. It also asks you whether you wish to reset 

the counters or not. Even if you reset these counters, 

the totals continue to increase.

BREW COUNT

SELECTIONS COUNTER

COUNTERS

GENERAL COUNTER

Содержание CLASSE 10

Страница 1: ...Manuale per il tecnico Manuel destin au technicien Handbuch f r den Techniker Technician s Manual Manual para el tecnico Manual para o t cnico 10 CLASSE 10 USB S RE USB S RE...

Страница 2: ...ungen die in diesem Handbuch beschrieben werden d rfen nur von ausgebildeten Technikern durchgef hrt werden GB The interventions and the programming procedures described in this manual may only be car...

Страница 3: ...5 2 1 7 Regeneration of the filter resins 5 2 1 8 Preventive maintenance 5 2 1 9 Boiler sensor 5 2 1 10 Level sensor 5 2 1 11 Error codes log 5 2 1 12 First time start up 5 2 1 13 Technical menu acce...

Страница 4: ...ically after 3 minutes if the set temperature has not yet been reached 2 1 Renewal the millk nozzle To increase the quantity of frothed milk change the standard emulsion nozzle indicated by a notch re...

Страница 5: ...ispensing from the groups for 30 sec Pauses for 30 sec Keeping esc pressed for 2 seconds during the cycle the current washing phase will stop and the next phase will take place It is advisable to alwa...

Страница 6: ...ess or To enter in a submenu press enter while to quit press esc When a submenu is accessed the editable value is displayed and changes can be made to it by pressing on the or keys If you make changes...

Страница 7: ...ing of the 3 4 tea keys provi des for different water temperatures ranging between 85 C and approx 60 C During dispensing the pump is activated It is also possible to set a dispensing option providing...

Страница 8: ...hat it is not displayed 5 2 1 9 Boiler sensor Setting the type of boiler pressure sensor Temperature sensor Pressure transducer default 5 2 1 10 Level sensor Sets the type of boiler water level sensor...

Страница 9: ...MAX level 5 2 4 2 No milk frothing Setting of the milk s final temperature and emulsion grade on a scale from 0 to MAX If set at level 0 the milk is only heated Increasing the emulsion level will incr...

Страница 10: ...repeated every hour until it is reset Please make the service time if the function is enabled and the set values have been reached this message will be then repeated every hour until it is reset SOLE...

Страница 11: ...The boiler safety devices can be reset by switching the machine OFF and then back ON again 8 THE CUP WARMER By pressing the relative button the display shows the following Depending on the darkened se...

Страница 12: ...g the relative error code on screen which will come flashing on alternatively to the customisation logos Because they are not serious these errors will allow the machine to keep running We nevertheles...

Страница 13: ...84 3 Edificio Trade 08028 Barcelona Spain Tel 34 902 884 275 Tel 34 934 923 414 Fax 34 93 496 57 01 www rancilio com info rancilio es USA Rancilio North America Inc 8102 S Lemont Rd 1200 Woodridge IL...

Страница 14: ...www rancilio com Cod 46900147 REV 03 2008...

Отзывы: