6.2. Operating mode

Once the temperature/pressure is reached, the date, 

the current time and the pressure data will stay on 

display  (for  20  sec.)  and  flash  alternatively  to  the 

customisation logos.

7. OPErATING SAfETY DEVIcES

When the coffee maker is switched ON, it checks 

whether there is enough water in the boiler.

7.1. 

If  the  water  level  is  inadequate,  the  machine 

tops  up  the  level  automatically.  If  this  does  not 

take  place  within  a  set  period,  the  boiler  filling 

operation is discontinued and a warning message 

is displayed: 

“G01 Water missing”

7.2. 

If the water presence check result is positive, the 

boiler heating resistances are enabled.

  If the set pressure is not reached within a specific 

time, the power supply to the heating resistances 

is cut off and a warning message is shown on the 

display:

“G02 Boiler Pressure low”

7.3. 

If the safety device for slow dispensing interve-

nes, the LED of the dispensing button must flash 

until the end of dispensing.

The boiler safety devices can be reset by switching 

the machine OFF and then back ON again

8. THE cUP-WArmEr

By pressing the relative button, the display shows 

the following:

Depending on the darkened segments it indicates the 

selected power status of the cup-warmer resistances 

(min – med – max – off).

passing from one level to the next is performed by 

pressing on the cup-warmer key.

If  one  of  the  two  time/doses  control  functions  are 

activated,  the  coffee  symbol  space  will  instead 

display:

otherwise:

“Brewing time ”

For energy saving purposes, the display will reduce 

its luminosity after one hour of continuous inactivity 

without dispensing anything. After two hours of con-

tinuous inactivity without dispensing anything, it will 

switch itself off altogether.

Coffee dispensing symbol

Hot water dispensing symbol

 

iSteam dispensing symbol

Date and time

Selected coffee dispensing group

Hot water dispensing

Type of hot water blending (4-TEA)

Milk warm-up display

Milk instant-temperature

10 

Boiler pressure

11 

Cup heater symbol

12 

Set-time symbol

Water charge symbol

14 

Boiler resistance ON symbol

During dispensing, the following is displayed:

Содержание CLASSE 10

Страница 1: ...Manuale per il tecnico Manuel destin au technicien Handbuch f r den Techniker Technician s Manual Manual para el tecnico Manual para o t cnico 10 CLASSE 10 USB S RE USB S RE...

Страница 2: ...ungen die in diesem Handbuch beschrieben werden d rfen nur von ausgebildeten Technikern durchgef hrt werden GB The interventions and the programming procedures described in this manual may only be car...

Страница 3: ...5 2 1 7 Regeneration of the filter resins 5 2 1 8 Preventive maintenance 5 2 1 9 Boiler sensor 5 2 1 10 Level sensor 5 2 1 11 Error codes log 5 2 1 12 First time start up 5 2 1 13 Technical menu acce...

Страница 4: ...ically after 3 minutes if the set temperature has not yet been reached 2 1 Renewal the millk nozzle To increase the quantity of frothed milk change the standard emulsion nozzle indicated by a notch re...

Страница 5: ...ispensing from the groups for 30 sec Pauses for 30 sec Keeping esc pressed for 2 seconds during the cycle the current washing phase will stop and the next phase will take place It is advisable to alwa...

Страница 6: ...ess or To enter in a submenu press enter while to quit press esc When a submenu is accessed the editable value is displayed and changes can be made to it by pressing on the or keys If you make changes...

Страница 7: ...ing of the 3 4 tea keys provi des for different water temperatures ranging between 85 C and approx 60 C During dispensing the pump is activated It is also possible to set a dispensing option providing...

Страница 8: ...hat it is not displayed 5 2 1 9 Boiler sensor Setting the type of boiler pressure sensor Temperature sensor Pressure transducer default 5 2 1 10 Level sensor Sets the type of boiler water level sensor...

Страница 9: ...MAX level 5 2 4 2 No milk frothing Setting of the milk s final temperature and emulsion grade on a scale from 0 to MAX If set at level 0 the milk is only heated Increasing the emulsion level will incr...

Страница 10: ...repeated every hour until it is reset Please make the service time if the function is enabled and the set values have been reached this message will be then repeated every hour until it is reset SOLE...

Страница 11: ...The boiler safety devices can be reset by switching the machine OFF and then back ON again 8 THE CUP WARMER By pressing the relative button the display shows the following Depending on the darkened se...

Страница 12: ...g the relative error code on screen which will come flashing on alternatively to the customisation logos Because they are not serious these errors will allow the machine to keep running We nevertheles...

Страница 13: ...84 3 Edificio Trade 08028 Barcelona Spain Tel 34 902 884 275 Tel 34 934 923 414 Fax 34 93 496 57 01 www rancilio com info rancilio es USA Rancilio North America Inc 8102 S Lemont Rd 1200 Woodridge IL...

Страница 14: ...www rancilio com Cod 46900147 REV 03 2008...

Отзывы: