background image

Page 3

STANDARD

1 Phase Motor Replacement

How to replace a 1 phase motor on Standard models.

  1.  Secure disconnect.
  2.  Move vacuum unit into an open area if needed.

  Note location and orientation of motor wires for proper installation.

  3.  Disconnect motor wires from 2T1, 4T2, and motor ground in Electrols.
 

Remove motor wire from cord grip.

  4.  Remove belt guard.
  5.  Loosen all four motor mounting bolts ½ turn from full tight.
  6.  Loosen belt tension bolts and remove belt(s).

 Note pulley and hub orientation for proper installation.

  7.  Remove motor pulley.
 

a.  

Set Screw Pulleys: 

 

  i.  Loosen motor pulley set screws and remove pulley.

 

b. 

Taper Lock Pulley:

 

  i.  See 

“Taper Lock Pulley Remove and Replace”

 procedure in the

 

    “Belt Replacement, Alignment, and Tensioning Service

 

 

Instruction”.

  8.  Remove motor mounting bolts and defective motor.
  9.  Install motor on base with motor mounting bolts previously removed.
10.  Replace shaft key.  Properly orientate pulley and pulley hub on motor
 

shaft.  

Do not tighten set screws or hub screws.

11.  Place belts over pump and motor pulleys.
12.  Tension and align belt.  See “Belt Replacement,

 

Alignment and

 

Tensioning Service Instructions”.

13.  Connect motor wires with proper orientation as noted.
14.  Replace vacuum unit in original spot.  Reattach exhaust outlet and
 

Filtrols intake hose couplings.

1 Phase Gray Box Electrols

Note: Gray Box Electrols have several variations

Motor Wires 2T1,

4T2, Motor Ground

Motor Ground Lug

Standard 550 Motor Bolts

Motor Mounting

Bolts  (4)

Belt Tension Bolts

Cord Grip

Содержание STANDARD 550

Страница 1: ...xxx xxx 1400 914 xxxx xxx BULLDOG MODELS Procedures Important Features 1 Phase Motor Replacement 3 Phase Motor Replacement 3 Phase Motor Startup Page 6 7 8 14 550 855 xxxx xxx QT 809 xxxx xxx QT E 809...

Страница 2: ...Page 2 STANDARD Standard Models Important Features...

Страница 3: ...ock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bolts and defective motor 9 Install motor on base with motor mounti...

Страница 4: ...dure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bolts and defective motor 9 Install motor on base with motor mounting bolts previously removed 10 Repl...

Страница 5: ...Page 5 NOTES...

Страница 6: ...Page 6 BULLDOG Bulldog Models Important Features...

Страница 7: ...ve motor mounting bolts and defective motor Note pulley orientation for proper installation 8 Loosen motor pulley set screws and remove motor pulley 9 Replace shaft key Properly orientate motor pulley...

Страница 8: ...8 Loosen motor pulley set screws and remove motor pulley 9 Replace shaft key Properly orientate pulley on motor shaft Do not tighten set screws 10 Position motor on base 11 Place belt over pump and mo...

Страница 9: ...Page 9 NOTES...

Страница 10: ...Page 10 BISON Bison Models Important Features...

Страница 11: ...7 Loosen pulley hub screws and remove motor pulley a See Taper Lock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bol...

Страница 12: ...for proper installation 7 Loosen pulley hub screws and remove motor pulley a See Taper Lock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8...

Страница 13: ...Page 13 NOTES...

Страница 14: ...kwards DO NOT ALLOW debris to enter pump 2 Check for correct pump rotation a Standard Models i Loosen Filtrols intake coupling and remove line ii Place hand by Filtrols intake to determine air ow b Bu...

Страница 15: ...Page 15 NOTES...

Страница 16: ...NOTES 3100 First Avenue Spear sh SD 57783 USA Web ramvac com Phone Fax 1 800 5 RAMVAC 1 605 642 4614 1 605 642 3776 SOF_7 2 3 01 145 Effective Date 21 Oct 05 Page 16 of 16...