BISON

1 Phase Motor Replacement

How to replace a 1 phase motor on Bison models

  1.  Secure disconnect.
  2.  Move vacuum unit into an open area if needed.

 Note location and orientation of motor wires for proper installation.

  3.  Disconnect motor wires.
 

a.  

Gray Box Electrols:

 

  i.  Disconnect motor wires from 2T1, 4T2, and motor ground in

 

    Electrols and remove wire from cord grip.

 

b.  

S1 Electrols:

 

  i.  Remove cover screws and cover from S1 Electrols.

 

  ii.  Disconnect motor wires  from M1, L1, and GND in S1 Electrols.

 

  iii.  Loosen cord grip on motor junction box and remove conduit.

 

  iv.  Carefully remove wires from conduit leaving the conduit

 

    attached to the S1 Electrols.

  4.  Remove belt guard.
  5.  Loosen all four motor mounting bolts ½ turn from full tight.
  6.  Loosen belt tension bolts and remove belts.
 

Note pulley and hub orientation for proper installation.

  7.  Loosen pulley hub screws and remove motor pulley.
 

a.  See 

“Taper Lock Pulley Remove and Replace”

 procedure in the

 

  “Belt Replacement, Alignment, and Tensioning Service Instruction”

  8.  Remove motor mounting bolts and defective motor.
  9.  Install motor on base with motor mounting bolts previously removed.
10.  Replace shaft key and properly orientate pulley and pulley hub on
 

motor shaft.  

Do not tighten hub screws.

11.  Place belts over pump and motor pulleys.
12.  Tension and align belt.  See “Belt Replacement,

 

Alignment and

 

Tensioning Service Instructions”.

13.  Connect motor wires with proper orientation as noted.
 

a.  

Gray Box Electrols:

 

  i.  Reverse step 3a.

 

b.  

S1 Electrols:

 

  i.  Reverse step 3b.

14.  Replace vacuum unit in original spot.  Reattach exhaust outlet
 

and Filtrols intake hose couplings.

 
  

1 Phase Gray Box Electrols

Note: Gray Box Electrols have several variations

Motor Wires 2T1, 4T2

Motor Ground

Motor Ground Lug

Bison Motor Bolts

Motor Mounting

Bolts  (4)

Motor Tension

Bolts

Motor Wires

L1, M1, GND

 S1 Electrols

Cord Grip

Cord Grip

Remove Cover

Screws (4)

Содержание STANDARD 550

Страница 1: ...xxx xxx 1400 914 xxxx xxx BULLDOG MODELS Procedures Important Features 1 Phase Motor Replacement 3 Phase Motor Replacement 3 Phase Motor Startup Page 6 7 8 14 550 855 xxxx xxx QT 809 xxxx xxx QT E 809...

Страница 2: ...Page 2 STANDARD Standard Models Important Features...

Страница 3: ...ock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bolts and defective motor 9 Install motor on base with motor mounti...

Страница 4: ...dure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bolts and defective motor 9 Install motor on base with motor mounting bolts previously removed 10 Repl...

Страница 5: ...Page 5 NOTES...

Страница 6: ...Page 6 BULLDOG Bulldog Models Important Features...

Страница 7: ...ve motor mounting bolts and defective motor Note pulley orientation for proper installation 8 Loosen motor pulley set screws and remove motor pulley 9 Replace shaft key Properly orientate motor pulley...

Страница 8: ...8 Loosen motor pulley set screws and remove motor pulley 9 Replace shaft key Properly orientate pulley on motor shaft Do not tighten set screws 10 Position motor on base 11 Place belt over pump and mo...

Страница 9: ...Page 9 NOTES...

Страница 10: ...Page 10 BISON Bison Models Important Features...

Страница 11: ...7 Loosen pulley hub screws and remove motor pulley a See Taper Lock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8 Remove motor mounting bol...

Страница 12: ...for proper installation 7 Loosen pulley hub screws and remove motor pulley a See Taper Lock Pulley Remove and Replace procedure in the Belt Replacement Alignment and Tensioning Service Instruction 8...

Страница 13: ...Page 13 NOTES...

Страница 14: ...kwards DO NOT ALLOW debris to enter pump 2 Check for correct pump rotation a Standard Models i Loosen Filtrols intake coupling and remove line ii Place hand by Filtrols intake to determine air ow b Bu...

Страница 15: ...Page 15 NOTES...

Страница 16: ...NOTES 3100 First Avenue Spear sh SD 57783 USA Web ramvac com Phone Fax 1 800 5 RAMVAC 1 605 642 4614 1 605 642 3776 SOF_7 2 3 01 145 Effective Date 21 Oct 05 Page 16 of 16...

Отзывы: