1056DOC – REV E
Page 8
•
If an Interface Control is included in the system the dip switch settings will need to be selected
to tell the OWL system what type of device is being controlled. Remove the four screws
holding the front cover on the Interface Control. The dip switch selector has two switches that
can be configured for AIR, VAC, WATER or AUX.
Owl Interface Control PCB Board
Follow the position settings printed on the circuit board to set the device to the appropriate
setting. Reinstall the cover. Connect the two-pin "RLY" terminals to the circuit that controls the
on/off functionality of the device being controlled.
•
Power up all equipment being controlled by the OWL System so that they are in a stand-by
non-running state. The LCD screen on RAMVAC compressors and vacuum units should light
up. Each vacuum or compressor should display "Local Standby" on the C2 or S2 Control LCD
screen. Also ensure the screen is illuminated on the OWL Touch Display in the office area.
The system is now ready to be programmed.