TROUBLESHOOTING
16
TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEMS
SERVICE
Returning/Purging Stage of Operation
If the TrakFast tool will not operate after following the above service directions,
return the tool to an Ramset Distributor Sales Representative for service.
800-241-5640
www.ramset.com
— Tool operated and
drove fastener, but
piston did not return
to up position .
— Combustion Chamber
does not drop after tool
cycles .
— Built-up dirt and debris
on Piston or in Nose
bore .
— Mushrooming of
Piston Tip .
— Exhaust ports on the
Sleeve are dirty or
clogged .
— Tool (Sleeve) or
O-Rings are dirty .
— Work Contacting
Element is bent,
or tool is dirty .
— Clean Piston and Nose bore with safety
solvent .
— Contact Ramset Distributor Sales
Representative for service .
— Return tool to Authorized Ramset Distributor
Sales Representative for service .
— Clean tool per Cleaning Procedure .
— Clean tool or replace Work Contacting
Element as required .