QUICK CHANGE NOSE
The T3SS tool is equipped with a quick
change nose. This feature allows the user
to change the work contact element to
meet various fastening needs. The work
contact element can be changed without
the use of tools by following these steps:
Removal
1.
Remove battery from the tool !!!
2. Firmly grasp the end of the
Work Contact Element and turn
it 90 degrees
3. Pull the Work Contact Element
from the tool.
Replace
1. Orient the Work Contact Element
so that the notched or flat portion
is toward the back or the tool
2. Firmly push the Work Contact
Element up into the nose piece.
3. Slightly twist the Work Contact
Element to be sure it is fully
engaged in the nose.
NOTE
: There
should be no open gap between the
shear block plate and the nose piece.
4. Insert the battery and operate
the tool.
Work Contact Elements
P/N: M150200 – To be used with fasteners
with pre-mounted 1/2” washers.
P/N: E150100 – To be used with straight
pins, fasteners with eyelets, and fastener
assemblies.
T3IF: Insulation Fastening System
QUICK CHANGE NOSE
QUICK CHANGE NOSE
11
Turn 90°
Pull
Note gap,
rotate work
contact
element until
gap disappears
- Two unique components are used:
• B0031IF-6A - Piston Assembly
• B0111IF - Work Contact Element
All operating and safety features are