- 5 -
RUN
START
14 GA
12 GA
10 GA
8 GA
120V Single Phase
1/2
4.7
5.0
up to 50'
50-100'
100-200'
200-300'
120V Single Phase
3/4
5.8
6.5
up to 50'
50-100'
100-200'
200-300'
AMPERES
MAXIMUM CONDUIT DISTANCE IN FEET
USING COPPER WIRE BY WIRE SIZE
INPUT POWER
MOTOR HP
RECOMMENDED WIRE GAUGE / VOLTAGE DROP CHART
Low voltage control wires must be run in a separate conduit to the operator.