5.

After marking the two spots, draw a line
between the two marks and extend it past
where the operator will be (see red line,

Figure 7

).

6.

The center of the pivot shaft, on the operator,
should be located on this line with at least a 2"
gap between the cover of the operator and the
gate when fully open.

II. Determining the Length of the Arms

1.

Now that the operator is in place, completely
close the gate.

2.

Get a string (green line) and tie one end to the
gate bracket (see blue dot 1, 

Figure 8

).

3.

Tie the other end to the pivot shaft on the
operator (see red dot 2, 

Figure 8

).

4.

Slowly open the gate.  While opening the
gate, place a finger against the string (see
point A, 

Figure 9

) and hold the string taunt

and level until the gate is fully open.

5.

When the gate is fully open, move your finger
until the string is overlapping the pivot shaft on
the operator (see *).

6.

Your finger, Point A, represents the pivot/hinge
bolt between the two arms.

7.

Mark the string where your finger is, Point A.

8.

The distance between point A and the pivot
shaft on the operator is represented by 'S'.

9.

The distance between point A and the bolt on
the gate bracket is represented by 'L'

10.

Cut the arms to resemble 

Figure 10

.

Measurements 'S' & 'L' are NOT the exact
lengths of the arms; the bracket and hardware
will affect the actual lengths of the arms.

 

2

Min. 

Figure 7

2

1

MIN 2”

 

2

Figure 8

 

2

1

2

Figure 6

 

A

Figure 9

 

Point A 

Figure 10

* If the wall is too close to

the operator to overlap
the string, place point A
as close to the wall as
room allows and then
proceed to step 6.

A

1

2

RAMSET

z

RAMSET

z

RAMSET

RAMSET

z

RAMSET

z

RAMSET

- 6 -

Содержание RAM-30 UL

Страница 1: ...Instruction Manual Model RAM 30 UL For Class I Vehicular Gate Operators No 545327 US C REV 5 02...

Страница 2: ......

Страница 3: ...button Controls 7 Electrical Connection 8 Intelligate PCB Motor Controller Specification Introduction 9 DIP Switch Configurations 9 10 Terminal Strip Connections 10 Control Input Description 10 Safety...

Страница 4: ...lation the following must be observed per UL 325 51 8 4 a Install the vehicular gate operator only when 1 The Vehicular Gate Operator is appropriate for the construction of the gate and the usage Clas...

Страница 5: ...m edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hardwired contact sensor shall be located and its wiri...

Страница 6: ...RAMSETz RAMSETz RAMSET R A M S E T z R A M S E T z R A M S E T 4 Alarm Horn Radio Receiver Terminal Strip Power Switch Electrical PBC Conduit Operators shown with covers removed Figure 1 Figure 2...

Страница 7: ...ing on local soil con dition 1 Construct form for mounting pad according to dimensions shown in Figure 3 and 4 2 Locate mounting pad according to dimensions given in illustration 3 Level top edge of f...

Страница 8: ...until the gate is fully open 5 When the gate is fully open move your finger until the string is overlapping the pivot shaft on the operator see 6 Your finger Point A represents the pivot hinge bolt be...

Страница 9: ...moving Close Pressing this button will cause the gate to close GATE TRAVEL ADJUSTMENT To adjust gate travel loosen set screw s on Cam Slam s and rotate to required posi tion Figure 11 LED must turn on...

Страница 10: ...onnect any wires when replacing the board nWARNING ALWAYS TURN OFF POWER WHEN SERVICING OPERATOR nCAUTION Check that gate is clear of people or obstructions BEFORE turning power ON to avoid injury MAI...

Страница 11: ...sitivity Adjusts the ERD for standard sensitivity on Adjusts the ERD sensitivity so that more pressure is need ed to stop the gate recommended only use in windy areas DIP SWITCH B1 SECURE CLOSE Secure...

Страница 12: ...witch features stops the motor from moving in one direc tion These wires are preset in factory and should not be moved Becomes active with a closed contact to common Phantom Keeps the gate open when t...

Страница 13: ...oop Open 3 button station Common Stop Close Reversing Loop Electronic Control Board must be serviced by a certified technician only Power must be turned OFF before servicing operator Power must be tur...

Страница 14: ...side Property Outside Property Figure 16 Phantom Loop Exit Loop 3 feet min 3 feet min 2 to 4 feet 3 feet min 4 feet min 6 feet min typical Do not twist wires inside loops 1 4 1 1 2 Reversing Sensors o...

Страница 15: ...eparate from power Keep conduits at least 3 inches apart Set dip switch B 8 to ON on operator designated to be Slave Set dip switch B 7 to reverse for RH operation SLAVE MODE REVERSE LOGIC ON Set Dip...

Страница 16: ...0 218 motor clamp 2 28 50 219 10 x 1 1 2 machine screw 2 29 50 220 plastic grommet 3 30 50 221 10 square nut 2 31 50 247 3 4 sealed ball bearings 2 32 50 253 3 4 collar shaft 2 33 50 265 3 16 x 3 4 ke...

Страница 17: ...46 52 47 52 38 50 14 51 39 5 12 6 21 52 49 56 33 37 55 24 11 12 48 23 9 8 28 30 27 2 34 25 10 4 44 26 1 35 45 41 32 42 31 36 53 29 7 22 14 MODEL RAM 30 UL PARTS DIAGRAM Figure 18 RAMSETz RAMSETz RAMS...

Страница 18: ...stem intended for use in an commercial location or building such as a multi family housing unit five or more single family units hotels garages retail stores or other buildings serv ing the general pu...

Отзывы: