DIP SWITCH B5: “LAG DELAY”

Lag on Close

One second lag on close

DIP SWITCH B6: “LAG MODE”

Lag on Open

One second lag on open

DIP SWITCH B7: “REVERSE LOGIC”
DIP FUNCTION

‘off’ Left hand operation – standard installation
‘on’ Right hand installations – Reverses motor & limit switches

without having to move any wires.

DIP SWITCH B8: “SLAVE MODE”

Master/slave

DIP FUNCTION

‘off’ Master mode – single gate operation.  All peripheral devices

are to be connected to the master operator.

‘on’ Slave mode – used to synchronize operation between two

gates.  Commands are received from the master through a
3-wire, shielded cable.

TERMINAL STRIP CONNECTIONS

CONTROL INPUT DESCRIPTIONS

AC Hot & Neutral

– 110 or 220 VAC to power the operator.

Voltage is predetermined at factory and cannot be changed
by the installer or technician.  

Close

– Closes the gate.  Used with three button stations or

pushbuttons.  Becomes active with a closed contact to com-
mon.

Exit

– Opens the gate.  Used with loop detectors, photo

eyes, keypads, phone entry systems, three-button sta-
tions…etc.  Becomes active with a closed contact to com-
mon. 

Firebox/SOS

– Opens the gate.  Used with fire dept. key

switches & controls.  Becomes active with a closed contact
to common, maintained or momentary depending on dip
switch B2 (see “dip switch features”).

Stop

– Stops the operator from moving. To be used as a

non-contact sensor such as a photo-beam, edge connector
or a three-button station. Becomes active with an open con-
tact to common when dip switch A7 is in the ‘on’ position
(see “dip switch features”).

Radio

– Operation depends on dip switch B3 (see “dip

switch features”).  Used with an RF receiver or pushbutton.
Becomes active with a closed contact to common.

SAFETY INPUT DESCRIPTION

Limit 1 & Limit 2 

– Depending on dip switch B7 (see “dip

switch features”), stops the motor from moving in one direc-
tion.  These wires are preset in factory and should not be
moved.  Becomes active with a closed contact to common.

Phantom 

– Keeps the gate open when the open limit switch

(A or B) is activated.  Used with loop detectors.  Becomes
active with a closed contact to common.

Rev Loop 

– Stops the gate from closing.  If the gate is open,

it holds the gate open.  If the gate is closing, it  stops and
reopens the gate.  If the gate is closed, the gate will remain
closed. The function can be altered with dip switch B4 (see
“dip switch features”).  Used with loop detectors, photo eyes,
safety edges…etc.  Becomes active with a closed contact to
common.

OUTPUTS

Mag 

(

+

)

& Mag 

(

-

)

Supplies 24VDC to a magnetic lock when gate is closed.  If
gate is not closed then no power is supplied.  Leave open if
not used.

Motor 1 & Motor 2

– Supplies power to the motor. Direction

depends on dip switch B7 (see “dip switch features”).  These
wires are preset and connected in the factory and should not
be moved.

24V Rect.

– Provides a rectified 24VDC for peripheral

accessories.

Solenoid

– Sends 110 VAC to a solenoid or other mechani-

cal lock.  Leave open if not used.

OTHER CONNECTIONS

Contact Closure Relay Outputs

Three separate isolated form-C relay outputs are provided.
Each relays contact is rated at 125VAC, 2 amps.

1.

Alarm – When ERD is triggered twice, before reaching a
fully closed or fully opened position, 24VDC is supplied
for 6 minutes and the control board will not accept any
commands.  After the 6 minutes the 24VDC is removed
and the board resets to normal operation.

2.

Triggers relay when gate is fully opened.  Used with indi-
cator lights, buzzers, beepers, misc. voltage magnetic
locks…etc.

3.

Triggers relay when gate is fully closed. Used with indi-
cator lights, buzzers, beepers, misc. voltage magnetic
locks…etc.

Note

: if both B5 &

B6 are 'on', there
will be NO lag on
the open or close.

Содержание RAM-1000 UL

Страница 1: ...No 545327 US C Instruction Manual Model RAM 1000 UL RAM 5500 UL For Class I II III IV Vehicular Gate Operators Rev 060202...

Страница 2: ...a rigid object or stop when an object activates the non contact sensors After adjusting the limit of travel retest the Vehicular Gate Operator Failure to adjust and retest the Vehicular Gate Operator...

Страница 3: ...nt protection device or devices must be located in the line of sight of the gate Outdoor or easily acces sible controls shall have a security feature to prevent unauthorized use f All warning signs an...

Страница 4: ...2 inches per second Reduction By worm gearbox continually lubricated in an oil bath By worm gearbox continually lubricated in an oil bath Finish Chassis Rust preventing Gold Zinc coated 3 16 sheet met...

Страница 5: ...rs and wire mesh 5 Mix concrete pour mixture into form Tamp mixture Level and finish surface after pouring is complete 6 Allow pad to cure 48 hours and remove forms Figure 1 6 1 2 6 MIN 4 MIN WALL 4 6...

Страница 6: ...IN FEET USING COPPER WIRE BY WIRE SIZE INPUT POWER MOTOR HP RECOMMENDED WIRE GAUGE VOLTAGE DROP CHART Low voltage control wires must be run in a separate conduit to the operator E D Rear Installation...

Страница 7: ...switches for manual operation of the gate see Figure 7 The open stop and close buttons can be utilized to set limit switches and verify proper system opera tion when installing or servicing an operat...

Страница 8: ...te is clear of people or obstructions BEFORE turning power ON to avoid injury nWARNING ALWAYS TURN OFF POWER WHEN SERVICING OPERATOR MAIN CPU CHIP OPEN FULLY OPEN FULLY CLOSED ALARM JP6 1 2 A 10 A JP5...

Страница 9: ...moving until a close contact is reached DIP SWITCH A8 LOW ERD HIGH ERD Sensitivity DIP FUNCTION off Normal ERD sensitivity Adjusts the ERD for standard sensitivity on Adjusts the ERD sensitivity so t...

Страница 10: ...UT DESCRIPTION Limit 1 Limit 2 Depending on dip switch B7 see dip switch features stops the motor from moving in one direc tion These wires are preset in factory and should not be moved Becomes active...

Страница 11: ...MOTOR 1 AC HOT NEUTRAL MAG SOLENOID CLOSE Figure 10 3 Wire Radio Receiver Capacitor Radio Terminal Strip Mag Lock Solenoid BL BK BK RD WH Legend RD Red WH White BL Blue GR Green Ground BK Black YL Ye...

Страница 12: ...INSTALLATION 6 feet min typical Inside Property Outside Property Twist wires outside of loop 3 feet min Reversing Loop Reversing Loop Exit Loop 3 feet min 3 feet min Figure 11 4 feet min 4 feet min 4...

Страница 13: ...7 limit switch shaft 1 32 50 247 3 4 ball bearrings 2 2 33 50 248 4 pin disc release 1 1 34 50 249 1 arbor release 1 1 35 50 250 41 b 27 clutch release sprocket 1 1 36 50 251 41 b 12 x 3 4 sprocket 1...

Страница 14: ...8 45 62 26 52 51 21 61 20 11 8 47 22 6 7 19 43 44 16 5 58 36 42 13 48 1 33 34 41 3 12 14 57 17 56 59 35 15 23 53 54 55 38 24 63 RAM 1000 UL PARTS DIAGRAM RAMSETz RAMSETz RAMSET R A M S E T z R A M S E...

Страница 15: ...re 14 4 20 32 31 39 25 37 18 60 2 58 27 62 26 52 51 21 61 20 11 8 29 22 6 7 19 43 44 16 5 58 36 42 13 28 40 33 34 41 3 12 14 57 17 56 59 35 15 23 53 54 55 38 24 63 RAMSETz RAMSETz RAMSET R A M S E T z...

Страница 16: ...system intended for use in a home of one to four single family dwellings or a garage or parking area associated therewith COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate o...

Отзывы: