RAMFAN EX150Li Скачать руководство пользователя страница 5

8

9

Main Interface 

Control Panel:

AC PWR

PUSH FOR 

WAKE | STOP

PUSH FOR

MAX

L

R

DC PWR
DC MAX
FAULT

BAT. FAULT

NO PWR

STORAGE

MODE

Intellisense

TM

 

E3

LIGHTS

SPEED

MAX

1

5

2

6

4

3

Number

Symbol

Indicate Function

1

Wake Button / Emergency Stop Button 

Press and hold WAKE button to start.

2

Maximum Speed (DC) Button 

Press MAX button for 2 seconds.

3

LED Scene Lights

On, off, on high or on low.

4

Speed Control

Controlled operation from 0 to full speed

5

Battery Status LED Lights

6

Ventilator Status LED Lights 

See table below for details.

MAX

MAX

L

R

BAT. FAULT

AC PWR

DC PWR
DC MAX
FAULT

NO PWR

STORAGE

MODE

LIGHTS

SPEED

Color

Status

Description

Off

NO PWR

Power is off

Green (Solid)

AC PWR

Ventilator is running on AC Power Supply

White (Solid)

DC PWR

Ventilator is running on DC Power Supply

White (Flashing)

DC MAX

Ventilator is running on Maximum speed - DC 

Power Supply

Red (Flashing)

FAULT

Fault on the ventilator

Yellow (Flashing) STORAGE MODE Storage/Transport Mode

Plug Types

The EX150Li is suitable for worldwide applications. A voltage converter is not needed. The 

unit includes a simple removable cord that allows the unit to operate up to 250 VAC:

Mainly used in 

Type

Order #

North and Central America,  Japan

B

EL-CUS-4762

France, Belgium, Germany, Austria, the 

Netherlands (and most European countries)

E/F

EL-CEU-4762

United Kingdom, Ireland, Malta, Malaysia and 

Singapore, Hong Kong, Nigeria

G

EL-83070-4762

Australia, New Zealand, Papua New Guinea and 

Argentina

I

EL-84040-4762

China, P.R.C. 

I

EL-84640-4762

If it becomes necessary to use a power cord with another plug standard, order the power 

cord that matches the electrical requirements of the country or area. The physical adapter 

for the outlet is interchangeable for use in different countries and allows you to swap the 

cable yourself into the socket. 

This page shows a selection of electric plugs we can currently offer for the EX150Li.

If you need a special solution, just inform your local Euramco representative about the 

specific. 

Содержание EX150Li

Страница 1: ...trol 5 6 7 8 8 7 6 5 THE WRITTEN PERMISSION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Owner s Manual EX150Li HIGH PERFORMANCE BATTERY FAN ...

Страница 2: ...on 11 Connection of Battery Pack 11 12 Battery Operation Procedures 13 14 Run Time 14 Charging Procedure 15 The Fuel Gauge 16 Battery Status Indicator Lights 17 Battery Pack Protection 17 Storage Transport Modes 18 How to Activate Storage Transport Mode 18 AC Power Cord 19 Operating Limitations 19 Lithium Ion Battery Maintenance Guideline 20 Overview 20 Storage 20 Recommendations 20 Maintenance an...

Страница 3: ...ets worldwide through five locations globally Warning Labels and Safety Instructions This is the safety alert symbol When you see this symbol on your ventilator or in this manual be alert to the potential for personal injury or damage to your equipment Be sure you understand all safety messages and always follow recommended precautions and safe operating practices Important safety information is p...

Страница 4: ...SION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EL6500 2 WHL EL6500 2 WHL 2 EXTENDED HANDLE 1 1 FIRST ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE INCHES MM TOLERANCES APPLY TO PRIMARY INCH DIMENSION AND ARE AS INDICATED RADII 015 MAX UNLESS SPECIFIED ON DRAWING PAR...

Страница 5: ...n the ventilator Yellow Flashing STORAGE MODE Storage Transport Mode Plug Types The EX150Li is suitable for worldwide applications A voltage converter is not needed The unit includes a simple removable cord that allows the unit to operate up to 250 VAC Mainly used in Type Order North and Central America Japan B EL CUS 4762 France Belgium Germany Austria the Netherlands and most European countries ...

Страница 6: ...it says Align battery EX150Li and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard Operational Modes Input Voltage 90 250VAC 50 60Hz The ventilator is capable of operating seamlessly in countries that supply electricity at either 120V AC 60 Hz or 240V AC 50 Hz without manual adjustments by the user Operation out of these limits can dam...

Страница 7: ...runtime and airflow performance When using two battery packs each pack functions independently and is isolated from the other so that if one pack should fail open circuit short circuit or become discharged the other battery will provide power to operate the system When using dual batteries it s important that both batteries be of the same charge level and ideally of the same age and condition It s...

Страница 8: ...ll charge beforehand and also 100 efficiency Read Factors that affect Battery Life section 2 Batteries Speed Level Knob At maximum speed 45 minutes 11 At maximum speed and DC Max button activated 30 minutes Max button activated MAX Make sure the battery pack is connect correctly into the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During...

Страница 9: ...R PUSH FOR WAKE STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX If the battery is charging the green indicator lights will horizontally scroll from left to right turning solid green when the battery is fully charged If the ventilator is running on battery power the estimated remaining battery time is shown If all the lights flash red this ...

Страница 10: ...E STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX How to activate Storage Transport Mode AC Power Cord CORD STORAGE This battery fan was designed to replace corded AC fans optimizing cordless operations AC power cord is designed to be removable for the convenience of those users who choose to operate cordless AC power connector is a Push P...

Страница 11: ...attery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller the discharge low DoD the less stress is enacted on the chemistry of the battery and the longer the battery will ultimately last Ideally operators should avoid full discharges and charge ...

Страница 12: ...n warrantable failures Maintenance Schedule Battery packs should be inspected regularly for mechanical damage Dropping or any other heavy impact may compromise water ingress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk...

Страница 13: ...ces accessories RAMFAN s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow These PPV blowers have proven to be effective in controlling airborne contaminates replacing interior air removing heat and supplementing fixed ventilation systems By pressurizing properly and controlling the resultant flow path these ...

Страница 14: ...ue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA No 128 HeZhou Road JiaoChuan Street ZhenHai District Ningbo China 315207 Phone 86 57487979390 Fax 86 57487979391 theteam euramcosafety com SINGAPORE 1 Fullerton Road 02 01 One Fullert...

Отзывы: